Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_7.0.0_Buildings.Fluid.Geothermal.Borefields.Validation.ConstantHeatInjection_100Boreholes.conf.json Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 7.0.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/package.mo) Running command: "" <> buildModelFMU(Buildings.Fluid.Geothermal.Borefields.Validation.ConstantHeatInjection_100Boreholes,fileNamePrefix="Buildings_7_0_0_Buildings_Fluid_Geothermal_Borefields_Validation_ConstantHeatInjection_100Boreholes",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/package.mo): time 2.243/2.243, allocations: 248.7 MB / 256.2 MB, free: 7.066 MB / 202.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001404/0.001404, allocations: 179.4 kB / 315.4 MB, free: 4.02 MB / 250.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.985/1.985, allocations: 205.3 MB / 0.5662 GB, free: 0.6055 MB / 410.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.001109/0.001108, allocations: 99.67 kB / 0.6704 GB, free: 5.809 MB / 0.5105 GB Notification: Performance of FrontEnd - loaded program: time 2.764e-05/2.767e-05, allocations: 4 kB / 0.7803 GB, free: 103.3 MB / 0.5417 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.1919/0.192, allocations: 106.3 MB / 0.8841 GB, free: 13.01 MB / 0.5573 GB Notification: Performance of FrontEnd - scodeFlatten: time 1.953/2.145, allocations: 0.4943 GB / 1.378 GB, free: 209.9 MB / 0.8698 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0003023/2.146, allocations: 103.5 kB / 1.379 GB, free: 209.9 MB / 0.8698 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/Utilities/Streams.mo:212:5-212:61:writable] Warning: Unused input variable nrow in function .Modelica.Utilities.Streams.readRealMatrix. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/Utilities/Streams.mo:213:5-213:64:writable] Warning: Unused input variable ncol in function .Modelica.Utilities.Streams.readRealMatrix. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/Fluid/Interfaces/LumpedVolumeDeclarations.mo:3:15-12:61:writable] Notification: From here: [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/Fluid/Geothermal/Borefields/Validation/ConstantHeatInjection_100Boreholes.mo:51:3-63:73:writable] Error: component hea contains the definition of a partial class Medium. Please redeclare it to any package compatible with Modelica.Media.Interfaces.PartialMedium. Error: Error occurred while flattening model Buildings.Fluid.Geothermal.Borefields.Validation.ConstantHeatInjection_100Boreholes Notification: Performance of FrontEnd: time 25.1/27.25, allocations: 4.241 GB / 5.62 GB, free: 56.04 MB / 0.9638 GB