Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_7.0.0_Buildings.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.Validation.FiniteDifference_1Week.conf.json Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 7.0.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/package.mo) Running command: "" <> buildModelFMU(Buildings.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.Validation.FiniteDifference_1Week,fileNamePrefix="Buildings_7_0_0_Buildings_Fluid_Geothermal_Borefields_BaseClasses_HeatTransfer_Validation_FiniteDifference_1Week",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/package.mo): time 2.256/2.256, allocations: 248.7 MB / 256.2 MB, free: 7.098 MB / 202.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001493/0.001492, allocations: 182.4 kB / 315.4 MB, free: 4.027 MB / 250.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.995/1.995, allocations: 205.3 MB / 0.5662 GB, free: 0.5898 MB / 410.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.001115/0.001115, allocations: 89.83 kB / 0.6704 GB, free: 5.793 MB / 0.5105 GB Notification: Performance of FrontEnd - loaded program: time 2.38e-05/2.376e-05, allocations: 4 kB / 0.7804 GB, free: 103.3 MB / 0.5417 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.1882/0.1883, allocations: 106.3 MB / 0.8841 GB, free: 12.98 MB / 0.5573 GB Notification: Performance of FrontEnd - scodeFlatten: time 0.893/1.081, allocations: 164 MB / 1.044 GB, free: 7.012 MB / 0.6667 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0003984/1.082, allocations: 105.6 kB / 1.044 GB, free: 6.949 MB / 0.6667 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/Fluid/Geothermal/Borefields/BaseClasses/HeatTransfer/GroundTemperatureResponse.mo:8:3-10:87:writable] Error: Array equation has unknown size in groTemRes.borFieDat.conDat.cooBor=borFieDat.conDat.cooBor. Error: Internal error - InstUtil.moveBindings: Mismatched number of equations and variables. Error: Error occurred while flattening model Buildings.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.Validation.FiniteDifference_1Week Notification: Performance of FrontEnd: time 0.2978/1.38, allocations: 33.75 MB / 1.077 GB, free: 9.242 MB / 0.698 GB