Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_7.0.0_Buildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.IntegratedPrimarySecondary.conf.json Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 7.0.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/package.mo) Running command: "" <> buildModelFMU(Buildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.IntegratedPrimarySecondary,fileNamePrefix="Buildings_7_0_0_Buildings_Applications_DataCenters_ChillerCooled_Equipment_Validation_IntegratedPrimarySecondary",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/package.mo): time 2.287/2.287, allocations: 248.7 MB / 256.2 MB, free: 7.059 MB / 202.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001505/0.001505, allocations: 189.1 kB / 315.4 MB, free: 3.988 MB / 250.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 2.106/2.106, allocations: 205.3 MB / 0.5662 GB, free: 0.5352 MB / 410.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.001212/0.001213, allocations: 86.12 kB / 0.6704 GB, free: 5.742 MB / 0.5105 GB Notification: Performance of FrontEnd - loaded program: time 2.313e-05/2.307e-05, allocations: 4 kB / 0.7803 GB, free: 103.3 MB / 0.5417 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.2304/0.2304, allocations: 106.3 MB / 0.8841 GB, free: 12.98 MB / 0.5573 GB Notification: Performance of FrontEnd - scodeFlatten: time 2.055/2.285, allocations: 0.5014 GB / 1.386 GB, free: 202.5 MB / 0.8698 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0003686/2.286, allocations: 103 kB / 1.386 GB, free: 202.5 MB / 0.8698 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/Applications/DataCenters/ChillerCooled/Equipment/IntegratedPrimarySecondary.mo:121:11-121:21:writable] Error: Type mismatch in binding pressure = Buildings.Fluid.Movers.BaseClasses.Characteristics.flowParameters$intWSEPriSec1$perPum$pressure({0, 0}, {0, 0}), expected subtype of record Buildings.Fluid.Movers.BaseClasses.Characteristics.flowParameters Real(min = 0.0, quantity = "VolumeFlowRate", unit = "m3/s")[2] V_flow; Real(min = 0.0, displayUnit = "Pa", quantity = "Pressure", unit = "Pa")[2] dp; end Buildings.Fluid.Movers.BaseClasses.Characteristics.flowParameters;, got type record Buildings.Fluid.Movers.BaseClasses.Characteristics.flowParameters$intWSEPriSec1$perPum$pressure Integer[2] V_flow; Integer[2] dp; end Buildings.Fluid.Movers.BaseClasses.Characteristics.flowParameters$intWSEPriSec1$perPum$pressure;. Error: Error occurred while flattening model Buildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.IntegratedPrimarySecondary Notification: Performance of FrontEnd: time 12.05/14.33, allocations: 2.31 GB / 3.695 GB, free: 2.184 MB / 0.9792 GB