Running: ./testmodel.py --libraries=/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/../OMCompiler/build/lib/omlibrary/ --ompython_omhome=/usr Buildings_6.0.0_Buildings.ThermalZones.Detailed.BaseClasses.Examples.InfraredRadiationExchange.conf.json Using package ModelicaServices with version 3.2.2 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OMCompiler/build/lib/omlibrary/ModelicaServices 3.2.2/package.mo) Using package Complex with version 3.2.2 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OMCompiler/build/lib/omlibrary/Complex 3.2.2.mo) Using package Modelica with version 3.2.2 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OMCompiler/build/lib/omlibrary/Modelica 3.2.2/package.mo) Using package Buildings with version 6.0.0 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/package.mo) Running command: "" <> buildModelFMU(Buildings.ThermalZones.Detailed.BaseClasses.Examples.InfraredRadiationExchange,fileNamePrefix="Buildings_6_0_0_Buildings_ThermalZones_Detailed_BaseClasses_Examples_InfraredRadiationExchange",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadModel(Buildings): time 4.131/4.131, allocations: 433.2 MB / 440.7 MB, free: 4.605 MB / 346.7 MB Notification: Performance of FrontEnd - loaded program: time 2.677e-05/2.675e-05, allocations: 3.406 kB / 0.5325 GB, free: 12.68 MB / 442.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.2345/0.2346, allocations: 98.73 MB / 0.6289 GB, free: 9.176 MB / 0.5105 GB Notification: Performance of FrontEnd - scodeFlatten: time 0.2706/0.5052, allocations: 146.3 MB / 0.7717 GB, free: 6.699 MB / 0.6511 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0003647/0.5057, allocations: 99.94 kB / 0.7718 GB, free: 6.602 MB / 0.6511 GB [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/ThermalZones/Detailed/BaseClasses/Examples/InfraredRadiationExchange.mo:13:11-13:36:writable] Error: Type mismatch in binding ove = Buildings.ThermalZones.Detailed.BaseClasses.Overhang$datConExtWin$ove(0, 0, 0, 0, false), expected subtype of record Buildings.ThermalZones.Detailed.BaseClasses.Overhang Real(min = 0.0, quantity = "Length", unit = "m") wL; Real(min = 0.0, quantity = "Length", unit = "m") wR; Real(min = 0.0, quantity = "Length", unit = "m") dep; Real(min = 0.0, quantity = "Length", unit = "m") gap; Boolean haveOverhang; end Buildings.ThermalZones.Detailed.BaseClasses.Overhang;, got type record Buildings.ThermalZones.Detailed.BaseClasses.Overhang$datConExtWin$ove Integer wL; Integer wR; Integer dep; Integer gap; Boolean haveOverhang; end Buildings.ThermalZones.Detailed.BaseClasses.Overhang$datConExtWin$ove;. Error: Error occurred while flattening model Buildings.ThermalZones.Detailed.BaseClasses.Examples.InfraredRadiationExchange Notification: Performance of FrontEnd: time 0.7747/1.28, allocations: 50.11 MB / 0.8208 GB, free: 123 MB / 0.6511 GB