OMSimulator --tempDir=temp_Buildings_6_0_0_Buildings_Fluid_Movers_Validation_PowerSimplified_fmu --startTime=0 --stopTime=200 --timeout=50 --tolerance=1e-06 Buildings_6_0_0_Buildings_Fluid_Movers_Validation_PowerSimplified.fmu info: Set temp directory to "/tmp/omsimulator" info: Set working directory to "." info: New temp directory has been created: "temp_Buildings_6_0_0_Buildings_Fluid_Movers_Validation_PowerSimplified_fmu" info: Set temp directory to "/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_6.0.0_Buildings.Fluid.Movers.Validation.PowerSimplified/temp_Buildings_6_0_0_Buildings_Fluid_Movers_Validation_PowerSimplified_fmu" info: Set working directory to "/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_6.0.0_Buildings.Fluid.Movers.Validation.PowerSimplified" info: New model "model" with corresponding temp directory "/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_6.0.0_Buildings.Fluid.Movers.Validation.PowerSimplified/temp_Buildings_6_0_0_Buildings_Fluid_Movers_Validation_PowerSimplified_fmu/model-jlglcmgj" warning: fmu (logStatusWarning): /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:352: The following assertion has been violated during initialization at time 0.000000 pump_dp.nominalValuesDefineDefaultPressureCurve assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. warning: fmu (logStatusWarning): /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:352: The following assertion has been violated during initialization at time 0.000000 pump_m_flow.nominalValuesDefineDefaultPressureCurve assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. info: maximum step size for 'model.root': 0.100000 info: Result file: model_res.mat (bufferSize=10) info: Final Statistics for 'model.root': NumSteps = 891 NumRhsEvals = 892 NumLinSolvSetups = 47 NumNonlinSolvIters = 891 NumNonlinSolvConvFails = 0 NumErrTestFails = 0 info: 2 warnings info: 0 errors