Running: ./testmodel.py --libraries=/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/../OMCompiler/build/lib/omlibrary/ --ompython_omhome=/usr Buildings_6.0.0_Buildings.Experimental.DistrictHeatingCooling.Plants.Validation.Plant_Carnot_T_ClosedLoop.conf.json Using package ModelicaServices with version 3.2.2 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OMCompiler/build/lib/omlibrary/ModelicaServices 3.2.2/package.mo) Using package Complex with version 3.2.2 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OMCompiler/build/lib/omlibrary/Complex 3.2.2.mo) Using package Modelica with version 3.2.2 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OMCompiler/build/lib/omlibrary/Modelica 3.2.2/package.mo) Using package Buildings with version 6.0.0 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/package.mo) Running command: "" <> buildModelFMU(Buildings.Experimental.DistrictHeatingCooling.Plants.Validation.Plant_Carnot_T_ClosedLoop,fileNamePrefix="Buildings_6_0_0_Buildings_Experimental_DistrictHeatingCooling_Plants_Validation_Plant_Carnot_T_ClosedLoop",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadModel(Buildings): time 4.199/4.199, allocations: 433.2 MB / 440.7 MB, free: 10.57 MB / 346.7 MB Notification: Performance of FrontEnd - loaded program: time 2.72e-05/2.712e-05, allocations: 4 kB / 0.5325 GB, free: 1.953 MB / 442.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.6201/0.6202, allocations: 98.71 MB / 0.6289 GB, free: 15.74 MB / 0.5105 GB Notification: Performance of FrontEnd - scodeFlatten: time 7.989/8.609, allocations: 2.516 GB / 3.145 GB, free: 161.7 MB / 0.823 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0003382/8.609, allocations: 94.95 kB / 3.145 GB, free: 161.7 MB / 0.823 GB [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OMCompiler/build/lib/omlibrary/Modelica 3.2.2/Blocks/Sources.mo:2346:7-2347:66:writable] Warning: Unused input variable tableAvailable in function .Modelica.Blocks.Sources.CombiTimeTable$TOut.getDerTableValue. [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OMCompiler/build/lib/omlibrary/Modelica 3.2.2/Blocks/Sources.mo:2312:7-2313:66:writable] Warning: Unused input variable tableAvailable in function .Modelica.Blocks.Sources.CombiTimeTable$TOut.getTableValue. [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OMCompiler/build/lib/omlibrary/Modelica 3.2.2/Blocks/Sources.mo:2358:7-2359:66:writable] Warning: Unused input variable tableAvailable in function .Modelica.Blocks.Sources.CombiTimeTable$TOut.getTableTimeTmin. [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OMCompiler/build/lib/omlibrary/Modelica 3.2.2/Blocks/Sources.mo:2369:7-2370:66:writable] Warning: Unused input variable tableAvailable in function .Modelica.Blocks.Sources.CombiTimeTable$TOut.getTableTimeTmax. [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/Experimental/DistrictHeatingCooling/Plants/HeatingCoolingCarnot_T.mo:77:3-91:69:writable] Error: Variable pla.coo: Cyclically dependent constants or parameters found in scope Buildings.Fluid.Chillers.Carnot_TEva$pla$coo: {COP_nominal,etaCarnot_nominal} (ignore with -d=ignoreCycles). Error: Error occurred while flattening model Buildings.Experimental.DistrictHeatingCooling.Plants.Validation.Plant_Carnot_T_ClosedLoop Notification: Performance of FrontEnd: time 1.26/9.869, allocations: 209.8 MB / 3.35 GB, free: 229.5 MB / 0.823 GB