Running: ./testmodel.py --libraries=/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/../OMCompiler/build/lib/omlibrary/ --ompython_omhome=/usr Buildings_6.0.0_Buildings.Examples.ScalableBenchmarks.BuildingVAV.ThermalZones.Validation.MultiZone.conf.json Using package ModelicaServices with version 3.2.2 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OMCompiler/build/lib/omlibrary/ModelicaServices 3.2.2/package.mo) Using package Complex with version 3.2.2 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OMCompiler/build/lib/omlibrary/Complex 3.2.2.mo) Using package Modelica with version 3.2.2 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OMCompiler/build/lib/omlibrary/Modelica 3.2.2/package.mo) Using package Buildings with version 6.0.0 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/package.mo) Running command: "" <> buildModelFMU(Buildings.Examples.ScalableBenchmarks.BuildingVAV.ThermalZones.Validation.MultiZone,fileNamePrefix="Buildings_6_0_0_Buildings_Examples_ScalableBenchmarks_BuildingVAV_ThermalZones_Validation_MultiZone",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadModel(Buildings): time 4.194/4.194, allocations: 433.2 MB / 440.7 MB, free: 4.594 MB / 346.7 MB Notification: Performance of FrontEnd - loaded program: time 2.398e-05/2.412e-05, allocations: 3.25 kB / 0.5325 GB, free: 12.67 MB / 442.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.2328/0.2329, allocations: 98.74 MB / 0.6289 GB, free: 9.141 MB / 0.5105 GB Notification: Performance of FrontEnd - scodeFlatten: time 7.864/8.097, allocations: 2.357 GB / 2.986 GB, free: 195.9 MB / 0.823 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0003595/8.097, allocations: 97.03 kB / 2.986 GB, free: 195.9 MB / 0.823 GB [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/Fluid/Sources/BaseClasses/Outside.mo:28:3-31:49:writable] Notification: From here: [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/Fluid/Sources/BaseClasses/PartialSource.mo:38:3-40:49:writable] Error: Duplicate elements (due to inherited elements) not identical: first element is: .Modelica.Blocks.Interfaces.RealInput[Medium.nX] X_in_internal(each final unit = "kg/kg", final quantity = Medium.substanceNames) "Needed to connect to conditional connector" second element is: .Modelica.Blocks.Interfaces.RealInput[Medium.nX] X_in_internal(each final unit = "kg/kg") "Needed to connect to conditional connector" Error: Error occurred while flattening model Buildings.Examples.ScalableBenchmarks.BuildingVAV.ThermalZones.Validation.MultiZone Notification: Performance of FrontEnd: time 1.815/9.912, allocations: 344.2 MB / 3.322 GB, free: 169.9 MB / 0.823 GB