Running command: "" <> buildModelFMU(Buildings.Experimental.DistrictHeatingCooling.Plants.Validation.Plant_Carnot_T_ClosedLoop,fileNamePrefix="Buildings_5_0_1_Buildings_Experimental_DistrictHeatingCooling_Plants_Validation_Plant_Carnot_T_ClosedLoop",fmuType="me",version="2.0",platforms={"dynamic"}) Notification: Performance of loadModel(Buildings): time 4.716/4.716, allocations: 404.1 MB / 411.3 MB, free: 348 kB / 314.7 MB Notification: Performance of FrontEnd - loaded program: time 2.342e-05/2.346e-05, allocations: 2.5 kB / 0.4945 GB, free: 1.312 MB / 410.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.6775/0.6775, allocations: 92.69 MB / 0.585 GB, free: 2.379 MB / 474.7 MB Notification: Performance of FrontEnd - scodeFlatten: time 8.621/9.298, allocations: 2.491 GB / 3.076 GB, free: 88.38 MB / 0.7761 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0003363/9.298, allocations: 94.19 kB / 3.076 GB, free: 88.32 MB / 0.7761 GB [/var/lib/hudson/slave/workspace/OpenModelica_TEST_LIBS/OpenModelica/OMCompiler/build/lib/omlibrary/Modelica 3.2.2/Blocks/Sources.mo:2346:7-2347:66:writable] Warning: Unused input variable tableAvailable in function .Modelica.Blocks.Sources.CombiTimeTable$TOut.getDerTableValue. [/var/lib/hudson/slave/workspace/OpenModelica_TEST_LIBS/OpenModelica/OMCompiler/build/lib/omlibrary/Modelica 3.2.2/Blocks/Sources.mo:2312:7-2313:66:writable] Warning: Unused input variable tableAvailable in function .Modelica.Blocks.Sources.CombiTimeTable$TOut.getTableValue. [/var/lib/hudson/slave/workspace/OpenModelica_TEST_LIBS/OpenModelica/OMCompiler/build/lib/omlibrary/Modelica 3.2.2/Blocks/Sources.mo:2358:7-2359:66:writable] Warning: Unused input variable tableAvailable in function .Modelica.Blocks.Sources.CombiTimeTable$TOut.getTableTimeTmin. [/var/lib/hudson/slave/workspace/OpenModelica_TEST_LIBS/OpenModelica/OMCompiler/build/lib/omlibrary/Modelica 3.2.2/Blocks/Sources.mo:2369:7-2370:66:writable] Warning: Unused input variable tableAvailable in function .Modelica.Blocks.Sources.CombiTimeTable$TOut.getTableTimeTmax. [/var/lib/hudson/slave/workspace/OpenModelica_TEST_LIBS/OpenModelica/OMCompiler/build/lib/omlibrary/Buildings 5.0.1/Experimental/DistrictHeatingCooling/Plants/HeatingCoolingCarnot_T.mo:77:3-91:69:writable] Error: Variable pla.coo: Cyclically dependent constants or parameters found in scope Buildings.Fluid.Chillers.Carnot_TEva$pla$coo: {COP_nominal,etaCarnot_nominal} (ignore with -d=ignoreCycles). Error: Error occurred while flattening model Buildings.Experimental.DistrictHeatingCooling.Plants.Validation.Plant_Carnot_T_ClosedLoop Notification: Performance of FrontEnd: time 1.461/10.76, allocations: 206.5 MB / 3.278 GB, free: 200.9 MB / 0.7761 GB