OMSimulator --tempDir=temp_BuildingSystems_BuildingSystems_Technologies_Chillers_Examples_CompressionChillerWithStorage_fmu --startTime=0 --stopTime=7200 --timeout=50 --tolerance=1e-06 BuildingSystems_BuildingSystems_Technologies_Chillers_Examples_CompressionChillerWithStorage.fmu info: Set temp directory to "/tmp/omsimulator" info: Set working directory to "." info: New temp directory has been created: "temp_BuildingSystems_BuildingSystems_Technologies_Chillers_Examples_CompressionChillerWithStorage_fmu" info: Set temp directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/BuildingSystems_BuildingSystems.Technologies.Chillers.Examples.CompressionChillerWithStorage/temp_BuildingSystems_BuildingSystems_Technologies_Chillers_Examples_CompressionChillerWithStorage_fmu" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/BuildingSystems_BuildingSystems.Technologies.Chillers.Examples.CompressionChillerWithStorage" info: New model "model" with corresponding temp directory "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/BuildingSystems_BuildingSystems.Technologies.Chillers.Examples.CompressionChillerWithStorage/temp_BuildingSystems_BuildingSystems_Technologies_Chillers_Examples_CompressionChillerWithStorage_fmu/model-9fhedc2n" warning: fmu (logStatusWarning): /home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:349: The following assertion has been violated during initialization at time 0.000000 pump.nominalValuesDefineDefaultPressureCurve assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. info: maximum step size for 'model.root': 0.100000 info: Result file: model_res.mat (bufferSize=10) info: Parameter model.root.fmu.chiller.COP_nominal.fileName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.fmu.chiller.COP_nominal.tableName will not be stored in the result file, because the signal type is not supported info: Final Statistics for 'model.root': NumSteps = 72015 NumRhsEvals = 72024 NumLinSolvSetups = 3609 NumNonlinSolvIters = 72023 NumNonlinSolvConvFails = 0 NumErrTestFails = 1 info: 1 warnings info: 0 errors