OMSimulator --tempDir=temp_AixLib_latest_AixLib_Media_Refrigerants_Validation_RefrigerantsFittedFormulas_RefrigerantsFittedFormulasR134a_fmu --startTime=0 --stopTime=6400 --timeout=50 --tolerance=1e-06 AixLib_latest_AixLib_Media_Refrigerants_Validation_RefrigerantsFittedFormulas_RefrigerantsFittedFormulasR134a.fmu info: Set temp directory to "/tmp/omsimulator" info: Set working directory to "." info: New temp directory has been created: "temp_AixLib_latest_AixLib_Media_Refrigerants_Validation_RefrigerantsFittedFormulas_RefrigerantsFittedFormulasR134a_fmu" info: Set temp directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/AixLib_latest_AixLib.Media.Refrigerants.Validation.RefrigerantsFittedFormulas.RefrigerantsFittedFormulasR134a/temp_AixLib_latest_AixLib_Media_Refrigerants_Validation_RefrigerantsFittedFormulas_RefrigerantsFittedFormulasR134a_fmu" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/AixLib_latest_AixLib.Media.Refrigerants.Validation.RefrigerantsFittedFormulas.RefrigerantsFittedFormulasR134a" info: New model "model" with corresponding temp directory "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/AixLib_latest_AixLib.Media.Refrigerants.Validation.RefrigerantsFittedFormulas.RefrigerantsFittedFormulasR134a/temp_AixLib_latest_AixLib_Media_Refrigerants_Validation_RefrigerantsFittedFormulas_RefrigerantsFittedFormulasR134a_fmu/model-13crf4ht" info: model doesn't contain any continuous state stdout | info | ... loading "External" from "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/AixLib_latest_AixLib.Media.Refrigerants.Validation.RefrigerantsFittedFormulas.RefrigerantsFittedFormulasR134a/temp_AixLib_latest_AixLib_Media_Refrigerants_Validation_RefrigerantsFittedFormulas_RefrigerantsFittedFormulasR134a_fmu/model-13crf4ht/temp/fmu/resources/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2-development/Resources/Media/Refrigerants/ValidationFittedFormulasR134a.txt" info: Result file: model_res.mat (bufferSize=10) info: Parameter model.root.fmu.extProp.fileName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.fmu.extProp.tableName will not be stored in the result file, because the signal type is not supported error: [operator()] Timeout occurred during simulation error: [fmi2logger] fmu (logStatusError): fmi2NewDiscreteStates: Illegal call sequence. fmi2NewDiscreteStates is not allowed in Terminated state. error: [doEventIteration] fmi2_import_new_discrete_states failed for FMU "model.root.fmu" error: [fmi2logger] fmu (logStatusError): fmi2EnterContinuousTimeMode: Illegal call sequence. fmi2EnterContinuousTimeMode is not allowed in Error state. error: [stepUntil] fmi2_import_enter_continuous_time_mode failed for FMU "model.root.fmu" error: [fmi2logger] fmu (logStatusError): fmi2CompletedIntegratorStep: Illegal call sequence. fmi2CompletedIntegratorStep is not allowed in Error state. error: [stepUntil] fmi2_import_completed_integrator_step failed for FMU "model.root.fmu" error: [updateSignals] failed to fetch variable extProp.verboseExtrapolation error: [stepUntil] fmi2_import_set_time failed for FMU "model.root.fmu"