OMSimulator --tempDir=temp_AixLib_latest_AixLib_BoundaryConditions_WeatherData_Validation_OverAYear_usingOneYearData_fmu --startTime=0 --stopTime=3.66336e+07 --timeout=50 --tolerance=1e-06 AixLib_latest_AixLib_BoundaryConditions_WeatherData_Validation_OverAYear_usingOneYearData.fmu info: Set temp directory to "/tmp/omsimulator" info: Set working directory to "." info: New temp directory has been created: "temp_AixLib_latest_AixLib_BoundaryConditions_WeatherData_Validation_OverAYear_usingOneYearData_fmu" info: Set temp directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/AixLib_latest_AixLib.BoundaryConditions.WeatherData.Validation.OverAYear_usingOneYearData/temp_AixLib_latest_AixLib_BoundaryConditions_WeatherData_Validation_OverAYear_usingOneYearData_fmu" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/AixLib_latest_AixLib.BoundaryConditions.WeatherData.Validation.OverAYear_usingOneYearData" info: New model "model" with corresponding temp directory "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/AixLib_latest_AixLib.BoundaryConditions.WeatherData.Validation.OverAYear_usingOneYearData/temp_AixLib_latest_AixLib_BoundaryConditions_WeatherData_Validation_OverAYear_usingOneYearData_fmu/model-zvljb6p4" info: model doesn't contain any continuous state info: Result file: model_res.mat (bufferSize=10) info: Variable model.root.fmu.weaDat.datRea.fileName will not be stored in the result file, because the signal type is not supported info: Variable model.root.fmu.weaDat.datRea.tableName will not be stored in the result file, because the signal type is not supported info: Variable model.root.fmu.weaDat.datRea30Min.fileName will not be stored in the result file, because the signal type is not supported info: Variable model.root.fmu.weaDat.datRea30Min.tableName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.fmu.weaDat.filNam will not be stored in the result file, because the signal type is not supported warning: fmu (logStatusWarning): /home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2-development/BoundaryConditions/WeatherData/BaseClasses/CheckDryBulbTemperature.mo:23: The following assertion has been violated at time 31823127.272727 noEvent(weaDat.weaBus.TDryBul > weaDat.cheTemDryBul.TMin) and noEvent(weaDat.weaBus.TDryBul < weaDat.cheTemDryBul.TMax) assert | error | In OverAYear_usingOneYearData.weaDat.cheTemDryBul: Weather data dry bulb temperature out of bounds. | | | | TIn = 348.356 error: [fmi2logger] fmu (logFmi2Call): fmi2CompletedIntegratorStep: terminated by an assertion. error: [stepUntil] fmi2_import_completed_integrator_step failed for FMU "model.root.fmu" info: 1 warnings info: 2 errors