Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr AixLib_AixLib.Systems.HydraulicModules.Example.Pump.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2-development/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica_DeviceDrivers 2.1.1/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/SDF master/package.mo", uses=false) Using package SDF with version 0.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/SDF master/package.mo) Using package Modelica_DeviceDrivers with version 2.1.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica_DeviceDrivers 2.1.1/package.mo) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Using package Modelica with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package AixLib with version 1.3.2 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2-development/package.mo) Running command: "" <> buildModelFMU(AixLib.Systems.HydraulicModules.Example.Pump,fileNamePrefix="AixLib_AixLib_Systems_HydraulicModules_Example_Pump",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(AixLib.Systems.HydraulicModules.Example.Pump,fileNamePrefix="AixLib_AixLib_Systems_HydraulicModules_Example_Pump",fmuType="me",version="2.0",platforms={"static"}) [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2-development/BoundaryConditions/InternalGains/Examples/InternalGains/Lights.mo:27:20-27:398:writable] Warning: Lexer treating \ as \\, since \ is not a valid Modelica escape sequence. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2-development/BoundaryConditions/InternalGains/Examples/InternalGains/Machines.mo:31:20-31:400:writable] Warning: Lexer treating \ as \\, since \ is not a valid Modelica escape sequence. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2-development/DataBase/CHP/CHPDataSimple/CHP_Cleanergy_C9G.mo:36:34-36:594:writable] Warning: Lexer treating \ as \\, since \ is not a valid Modelica escape sequence. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2-development/DataBase/CHP/CHPDataSimple/CHP_XRGI_9kWel.mo:25:34-25:588:writable] Warning: Lexer treating \ as \\, since \ is not a valid Modelica escape sequence. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2-development/DataBase/CHP/CHPDataSimple/CHP_XRGI_9kWel.mo:25:34-25:3852:writable] Warning: Lexer treating \ as \\, since \ is not a valid Modelica escape sequence. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2-development/DataBase/Weather/SurfaceOrientation/SurfaceOrientationData_NE_SE_SW_NW_Hor.mo:5:35-5:324:writable] Warning: Lexer treating \ as \\, since \ is not a valid Modelica escape sequence. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2-development/DataBase/Weather/SurfaceOrientation/SurfaceOrientationData_N_E_S_W_Hor.mo:5:35-5:320:writable] Warning: Lexer treating \ as \\, since \ is not a valid Modelica escape sequence. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2-development/DataBase/Weather/SurfaceOrientation/SurfaceOrientationData_N_E_S_W_RoofN_Roof_S.mo:5:35-5:362:writable] Warning: Lexer treating \ as \\, since \ is not a valid Modelica escape sequence. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2-development/Obsolete/YearIndependent/FastHVAC/Components/HeatExchangers/RadiatorMultiLayer.mo:265:34-265:6228:writable] Warning: Lexer treating \ as \\, since \ is not a valid Modelica escape sequence. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2-development/Obsolete/YearIndependent/FastHVAC/Components/HeatExchangers/RadiatorMultiLayer.mo:265:34-265:6853:writable] Warning: Lexer treating \ as \\, since \ is not a valid Modelica escape sequence. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2-development/Obsolete/YearIndependent/FastHVAC/Components/HeatExchangers/RadiatorMultiLayer.mo:265:34-265:8435:writable] Warning: Lexer treating \ as \\, since \ is not a valid Modelica escape sequence. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2-development/Obsolete/YearIndependent/FastHVAC/Components/HeatExchangers/RadiatorMultiLayer.mo:265:34-265:9369:writable] Warning: Lexer treating \ as \\, since \ is not a valid Modelica escape sequence. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2-development/Obsolete/YearIndependent/FastHVAC/Components/HeatExchangers/RadiatorMultiLayer.mo:265:34-265:11505:writable] Warning: Lexer treating \ as \\, since \ is not a valid Modelica escape sequence. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2-development/Obsolete/YearIndependent/FastHVAC/Components/HeatExchangers/RadiatorMultiLayer.mo:265:34-265:12875:writable] Warning: Lexer treating \ as \\, since \ is not a valid Modelica escape sequence. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2-development/ThermalZones/HighOrder/Components/DryAir/InfiltrationRate_DIN12831.mo:20:192-20:2066:writable] Warning: Lexer treating \ as \\, since \ is not a valid Modelica escape sequence. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2-development/ThermalZones/HighOrder/Components/DryAir/InfiltrationRate_DIN12831.mo:20:192-20:4252:writable] Warning: Lexer treating \ as \\, since \ is not a valid Modelica escape sequence. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2-development/ThermalZones/HighOrder/Components/Examples/DryAir/DryAir_test.mo:71:18-71:405:writable] Warning: Lexer treating \ as \\, since \ is not a valid Modelica escape sequence. Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2-development/package.mo): time 1.966/1.966, allocations: 265.1 MB / 272.6 MB, free: 8.566 MB / 218.8 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.00146/0.001461, allocations: 184.8 kB / 330.1 MB, free: 44 kB / 266.8 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo): time 1.601/1.601, allocations: 221.5 MB / 0.5946 GB, free: 14.21 MB / 458.8 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.001062/0.001062, allocations: 99.16 kB / 0.6998 GB, free: 2.34 MB / 0.5418 GB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica_DeviceDrivers 2.1.1/package.mo): time 0.05625/0.05625, allocations: 11.9 MB / 0.8165 GB, free: 65.25 MB / 0.5418 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/SDF master/package.mo:9:42-9:258:writable] Notification: This is an open source dummy package of a commercial library. If you want it to be supported, you will need to add an implemention on our github repository: https://github.com/Modelica-OpenVendorSpecificLibraries. Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/SDF master/package.mo): time 0.0005473/0.0005475, allocations: 18.22 kB / 0.9245 GB, free: 87.03 MB / 0.573 GB Notification: Performance of FrontEnd - loaded program: time 2.374e-05/2.377e-05, allocations: 4 kB / 1.04 GB, free: 8.598 MB / 0.5887 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.3207/0.3208, allocations: 110.2 MB / 1.147 GB, free: 10.27 MB / 0.698 GB Notification: Performance of FrontEnd - scodeFlatten: time 2.014/2.335, allocations: 463.8 MB / 1.6 GB, free: 287.3 MB / 0.9324 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0003701/2.336, allocations: 90.14 kB / 1.601 GB, free: 287.3 MB / 0.9324 GB Notification: Performance of FrontEnd - DAE generated: time 8.482/10.82, allocations: 2.082 GB / 3.683 GB, free: 50.4 MB / 1.011 GB Notification: Performance of FrontEnd: time 1.874e-06/10.82, allocations: 3.938 kB / 3.683 GB, free: 50.39 MB / 1.011 GB Notification: Performance of Transformations before backend: time 0.001452/10.82, allocations: 148.7 kB / 3.683 GB, free: 50.37 MB / 1.011 GB Notification: Model statistics after passing the front-end and creating the data structures used by the back-end: * Number of equations: 912 * Number of variables: 912 Notification: Performance of Generate backend data structure: time 0.02268/10.84, allocations: 5.391 MB / 3.688 GB, free: 47.37 MB / 1.011 GB Notification: Performance of prepare preOptimizeDAE: time 6.064e-05/10.84, allocations: 14.62 kB / 3.688 GB, free: 47.37 MB / 1.011 GB Notification: Performance of preOpt normalInlineFunction (simulation): time 0.006495/10.85, allocations: 0.7684 MB / 3.689 GB, free: 47.02 MB / 1.011 GB Notification: Performance of preOpt evaluateParameters (simulation): time 0.04145/10.89, allocations: 13.17 MB / 3.702 GB, free: 40.98 MB / 1.011 GB Notification: Performance of preOpt simplifyIfEquations (simulation): time 0.0004784/10.89, allocations: 115.9 kB / 3.702 GB, free: 40.98 MB / 1.011 GB Notification: Performance of preOpt expandDerOperator (simulation): time 0.002725/10.89, allocations: 229 kB / 3.702 GB, free: 40.97 MB / 1.011 GB Notification: Performance of preOpt removeEqualFunctionCalls (simulation): time 0.01121/10.9, allocations: 3.156 MB / 3.705 GB, free: 39.54 MB / 1.011 GB Notification: Performance of preOpt clockPartitioning (simulation): time 0.012/10.92, allocations: 3.763 MB / 3.709 GB, free: 37.74 MB / 1.011 GB Notification: Performance of preOpt findStateOrder (simulation): time 0.0001152/10.92, allocations: 7.25 kB / 3.709 GB, free: 37.73 MB / 1.011 GB Notification: Performance of preOpt replaceEdgeChange (simulation): time 0.0004288/10.92, allocations: 6.75 kB / 3.709 GB, free: 37.73 MB / 1.011 GB Notification: Performance of preOpt inlineArrayEqn (simulation): time 0.0001297/10.92, allocations: 139.4 kB / 3.709 GB, free: 37.72 MB / 1.011 GB Warning: The model contains alias variables with conflicting start and/or nominal values. It is recommended to resolve the conflicts, because otherwise the system could be hard to solve. To print the conflicting alias sets and the chosen candidates please use -d=aliasConflicts. Notification: Performance of preOpt removeSimpleEquations (simulation): time 0.03406/10.95, allocations: 24.12 MB / 3.732 GB, free: 15.71 MB / 1.011 GB Notification: Performance of preOpt comSubExp (simulation): time 0.003389/10.96, allocations: 2.317 MB / 3.735 GB, free: 13.41 MB / 1.011 GB Notification: Performance of preOpt resolveLoops (simulation): time 0.001606/10.96, allocations: 1.276 MB / 3.736 GB, free: 12.13 MB / 1.011 GB Warning: The model contains alias variables with conflicting start and/or nominal values. It is recommended to resolve the conflicts, because otherwise the system could be hard to solve. To print the conflicting alias sets and the chosen candidates please use -d=aliasConflicts. Notification: Performance of preOpt evalFunc (simulation): time 0.01443/10.97, allocations: 10.63 MB / 3.746 GB, free: 480 kB / 1.011 GB Notification: Performance of preOpt encapsulateWhenConditions (simulation): time 4.133e-05/10.97, allocations: 64.5 kB / 3.746 GB, free: 408 kB / 1.011 GB Notification: Performance of preOpt simplifyInStream (simulation): time 0.003522/10.97, allocations: 265.8 kB / 3.747 GB, free: 140 kB / 1.011 GB Notification: Performance of pre-optimization done (n=215): time 6.041e-06/10.97, allocations: 3.938 kB / 3.747 GB, free: 136 kB / 1.011 GB Notification: Performance of matching and sorting (n=215): time 0.01158/10.99, allocations: 3.545 MB / 3.75 GB, free: 12.57 MB / 1.026 GB Notification: Performance of inlineWhenForInitialization (initialization): time 5.635e-05/10.99, allocations: 77.34 kB / 3.75 GB, free: 12.48 MB / 1.026 GB Notification: Performance of selectInitializationVariablesDAE (initialization): time 0.009776/11, allocations: 4.386 MB / 3.754 GB, free: 8.117 MB / 1.026 GB Notification: Performance of collectPreVariables (initialization): time 0.001036/11, allocations: 25.7 kB / 3.754 GB, free: 8.086 MB / 1.026 GB Notification: Performance of collectInitialEqns (initialization): time 0.002913/11, allocations: 2.574 MB / 3.757 GB, free: 5.492 MB / 1.026 GB Notification: Performance of collectInitialBindings (initialization): time 0.00151/11, allocations: 0.7274 MB / 3.758 GB, free: 4.754 MB / 1.026 GB Notification: Performance of simplifyInitialFunctions (initialization): time 0.0001455/11, allocations: 0 / 3.758 GB, free: 4.754 MB / 1.026 GB Notification: Performance of setup shared object (initialization): time 0.0002589/11, allocations: 415.7 kB / 3.758 GB, free: 4.344 MB / 1.026 GB Notification: Performance of preBalanceInitialSystem (initialization): time 0.002224/11, allocations: 1.056 MB / 3.759 GB, free: 3.285 MB / 1.026 GB Notification: Performance of partitionIndependentBlocks (initialization): time 0.003031/11.01, allocations: 1.84 MB / 3.761 GB, free: 1.09 MB / 1.026 GB Notification: Performance of analyzeInitialSystem (initialization): time 0.005859/11.01, allocations: 1.736 MB / 3.763 GB, free: 15.34 MB / 1.042 GB Notification: Performance of solveInitialSystemEqSystem (initialization): time 2.127e-05/11.01, allocations: 4 kB / 3.763 GB, free: 15.33 MB / 1.042 GB Notification: Performance of matching and sorting (n=358) (initialization): time 0.01266/11.03, allocations: 4.341 MB / 3.767 GB, free: 10.93 MB / 1.042 GB Notification: Performance of prepare postOptimizeDAE: time 0.9674/11.99, allocations: 10.32 MB / 3.777 GB, free: 85.66 MB / 1.042 GB Notification: Performance of postOpt simplifyComplexFunction (initialization): time 0.0002207/11.99, allocations: 28.72 kB / 3.777 GB, free: 85.66 MB / 1.042 GB Notification: Performance of postOpt tearingSystem (initialization): time 0.003522/12, allocations: 0.8162 MB / 3.778 GB, free: 85.61 MB / 1.042 GB Notification: Performance of postOpt solveSimpleEquations (initialization): time 0.003019/12, allocations: 0.5825 MB / 3.778 GB, free: 85.61 MB / 1.042 GB Notification: Performance of postOpt calculateStrongComponentJacobians (initialization): time 0.007171/12.01, allocations: 7.593 MB / 3.786 GB, free: 79.91 MB / 1.042 GB Notification: Performance of postOpt simplifyAllExpressions (initialization): time 0.007178/12.01, allocations: 269.6 kB / 3.786 GB, free: 79.91 MB / 1.042 GB Notification: Performance of postOpt collapseArrayExpressions (initialization): time 0.001094/12.02, allocations: 169.3 kB / 3.786 GB, free: 79.91 MB / 1.042 GB Notification: Performance of prepare postOptimizeDAE: time 1.572e-05/12.02, allocations: 5.469 kB / 3.786 GB, free: 79.91 MB / 1.042 GB Notification: Performance of postOpt replaceHomotopyWithSimplified (initialization): time 0.0134/12.03, allocations: 3.696 MB / 3.79 GB, free: 79.78 MB / 1.042 GB Notification: Performance of postOpt simplifyComplexFunction (initialization): time 0.0001623/12.03, allocations: 29.44 kB / 3.79 GB, free: 79.78 MB / 1.042 GB Notification: Performance of postOpt tearingSystem (initialization): time 0.004185/12.03, allocations: 0.875 MB / 3.791 GB, free: 79.72 MB / 1.042 GB Notification: Performance of postOpt solveSimpleEquations (initialization): time 0.003255/12.04, allocations: 0.5779 MB / 3.791 GB, free: 79.72 MB / 1.042 GB Notification: Performance of postOpt calculateStrongComponentJacobians (initialization): time 0.01759/12.05, allocations: 11.03 MB / 3.802 GB, free: 72.86 MB / 1.042 GB Notification: Performance of postOpt simplifyAllExpressions (initialization): time 0.008326/12.06, allocations: 261.9 kB / 3.802 GB, free: 72.86 MB / 1.042 GB Notification: Performance of postOpt collapseArrayExpressions (initialization): time 0.001538/12.06, allocations: 161.1 kB / 3.802 GB, free: 72.86 MB / 1.042 GB Notification: Model statistics after passing the back-end for initialization: * Number of independent subsystems: 98 * Number of states: 0 () * Number of discrete variables: 0 () * Number of discrete states: 0 () * Top-level inputs: 0 Notification: Strong component statistics for initialization (311): * Single equations (assignments): 297 * Array equations: 1 * Algorithm blocks: 0 * Record equations: 6 * When equations: 0 * If-equations: 0 * Equation systems (linear and non-linear blocks): 0 * Torn equation systems: 7 * Mixed (continuous/discrete) equation systems: 0 Notification: Torn system details for strict tearing set: * Linear torn systems: 3 {(1,100.0%) 2,(1,100.0%) 2,(1,100.0%) 2} * Non-linear torn systems: 4 {1 5,1 5,1 5,1 11} Notification: Performance of prepare postOptimizeDAE: time 0.002377/12.07, allocations: 179.4 kB / 3.803 GB, free: 72.75 MB / 1.042 GB Notification: Performance of postOpt createAliasVarsForOutputStates (simulation): time 0.01607/12.08, allocations: 3.267 MB / 3.806 GB, free: 72.6 MB / 1.042 GB Notification: Performance of postOpt lateInlineFunction (simulation): time 0.00275/12.09, allocations: 482.9 kB / 3.806 GB, free: 72.46 MB / 1.042 GB Notification: Performance of postOpt wrapFunctionCalls (simulation): time 0.01434/12.1, allocations: 4.217 MB / 3.81 GB, free: 72.16 MB / 1.042 GB Notification: Performance of postOpt inlineArrayEqn (simulation): time 7.145e-05/12.1, allocations: 41.38 kB / 3.81 GB, free: 72.16 MB / 1.042 GB Notification: Performance of postOpt constantLinearSystem (simulation): time 1.667e-05/12.1, allocations: 0.75 kB / 3.81 GB, free: 72.16 MB / 1.042 GB Notification: Performance of postOpt simplifysemiLinear (simulation): time 0.007996/12.11, allocations: 3.09 MB / 3.813 GB, free: 71.83 MB / 1.042 GB Warning: The model contains alias variables with conflicting start and/or nominal values. It is recommended to resolve the conflicts, because otherwise the system could be hard to solve. To print the conflicting alias sets and the chosen candidates please use -d=aliasConflicts. Notification: Performance of postOpt removeSimpleEquations (simulation): time 0.02544/12.13, allocations: 9.496 MB / 3.823 GB, free: 70.82 MB / 1.042 GB Notification: Performance of postOpt simplifyComplexFunction (simulation): time 4.107e-05/12.13, allocations: 10.59 kB / 3.823 GB, free: 70.82 MB / 1.042 GB Notification: Performance of postOpt solveSimpleEquations (simulation): time 0.001838/12.14, allocations: 383.7 kB / 3.823 GB, free: 70.82 MB / 1.042 GB Notification: Performance of postOpt tearingSystem (simulation): time 0.001903/12.14, allocations: 0.5107 MB / 3.824 GB, free: 70.77 MB / 1.042 GB Notification: Performance of postOpt inputDerivativesUsed (simulation): time 0.0002837/12.14, allocations: 58.38 kB / 3.824 GB, free: 70.77 MB / 1.042 GB Notification: Performance of postOpt calculateStrongComponentJacobians (simulation): time 0.005257/12.14, allocations: 6.9 MB / 3.83 GB, free: 65.1 MB / 1.042 GB Notification: Performance of postOpt calculateStateSetsJacobians (simulation): time 1.173e-05/12.14, allocations: 3.781 kB / 3.83 GB, free: 65.1 MB / 1.042 GB Notification: Performance of postOpt symbolicJacobian (simulation): time 0.01418/12.16, allocations: 5.375 MB / 3.836 GB, free: 64.26 MB / 1.042 GB Notification: Performance of postOpt removeConstants (simulation): time 0.00491/12.16, allocations: 1.203 MB / 3.837 GB, free: 63.9 MB / 1.042 GB Notification: Performance of postOpt simplifyTimeIndepFuncCalls (simulation): time 0.002341/12.16, allocations: 13.84 kB / 3.837 GB, free: 63.9 MB / 1.042 GB Notification: Performance of postOpt simplifyAllExpressions (simulation): time 0.005367/12.17, allocations: 247 kB / 3.837 GB, free: 63.89 MB / 1.042 GB Notification: Performance of postOpt findZeroCrossings (simulation): time 0.000395/12.17, allocations: 173.3 kB / 3.837 GB, free: 63.89 MB / 1.042 GB Notification: Performance of postOpt collapseArrayExpressions (simulation): time 0.0004062/12.17, allocations: 124.6 kB / 3.837 GB, free: 63.89 MB / 1.042 GB Notification: Performance of sorting global known variables: time 0.008824/12.18, allocations: 3.319 MB / 3.84 GB, free: 63.71 MB / 1.042 GB Notification: Performance of sort global known variables: time 4.11e-07/12.18, allocations: 1.094 kB / 3.84 GB, free: 63.71 MB / 1.042 GB Notification: Performance of remove unused functions: time 0.02261/12.2, allocations: 3.332 MB / 3.844 GB, free: 63.54 MB / 1.042 GB Notification: Model statistics after passing the back-end for simulation: * Number of independent subsystems: 5 * Number of states: 26 (Unmixed.senT_a1.T,Unmixed.senT_a2.T,Unmixed.senT_b1.T,Unmixed.senT_b2.T,Unmixed.PT1_b2.y,Unmixed.PT1_b1.y,Unmixed.PT1_a1.y,Unmixed.PT1_a2.y,Unmixed.PumpInterface.pump.vol.dynBal.U,Unmixed.PumpInterface.pump.filter.s[1],Unmixed.PumpInterface.pump.filter.s[2],Unmixed.pipe1.plugFlowPipe.del.x,Unmixed.pipe1.plugFlowPipe.timDel.x,Unmixed.pipe1.plugFlowPipe.vol_b.dynBal.U,Unmixed.pipe1.plugFlowPipe.vol_a.dynBal.U,Unmixed.pipe1.Insulation.CylindricLoad1.heatCapacitor.T,Unmixed.pipe2.plugFlowPipe.del.x,Unmixed.pipe2.plugFlowPipe.timDel.x,Unmixed.pipe2.plugFlowPipe.vol_b.dynBal.U,Unmixed.pipe2.plugFlowPipe.vol_a.dynBal.U,Unmixed.pipe2.Insulation.CylindricLoad1.heatCapacitor.T,Unmixed.pipe3.plugFlowPipe.del.x,Unmixed.pipe3.plugFlowPipe.timDel.x,Unmixed.pipe3.plugFlowPipe.vol_b.dynBal.U,Unmixed.pipe3.plugFlowPipe.vol_a.dynBal.U,Unmixed.pipe3.Insulation.CylindricLoad1.heatCapacitor.T) * Number of discrete variables: 0 () * Number of discrete states: 0 () * Top-level inputs: 0 Notification: Strong component statistics for simulation (226): * Single equations (assignments): 183 * Array equations: 0 * Algorithm blocks: 0 * Record equations: 36 * When equations: 0 * If-equations: 0 * Equation systems (linear and non-linear blocks): 0 * Torn equation systems: 7 * Mixed (continuous/discrete) equation systems: 0 Notification: Torn system details for strict tearing set: * Linear torn systems: 3 {(1,100.0%) 2,(1,100.0%) 2,(1,100.0%) 2} * Non-linear torn systems: 4 {1 7,1 7,1 7,1 11} Notification: Performance of Backend phase and start with SimCode phase: time 0.02356/12.23, allocations: 9.15 MB / 3.853 GB, free: 61.29 MB / 1.042 GB Notification: Performance of simCode: created initialization part: time 0.01268/12.24, allocations: 5.668 MB / 3.858 GB, free: 60.11 MB / 1.042 GB Notification: Performance of simCode: created event and clocks part: time 1.768e-05/12.24, allocations: 2.062 kB / 3.858 GB, free: 60.11 MB / 1.042 GB Notification: Performance of simCode: created simulation system equations: time 0.003703/12.24, allocations: 1.878 MB / 3.86 GB, free: 59.6 MB / 1.042 GB Notification: Performance of simCode: created of all other equations (e.g. parameter, nominal, assert, etc): time 0.01628/12.26, allocations: 2.445 MB / 3.862 GB, free: 59.57 MB / 1.042 GB Notification: Performance of simCode: created linear, non-linear and system jacobian parts: time 0.03492/12.29, allocations: 9.597 MB / 3.872 GB, free: 57.47 MB / 1.042 GB Notification: Performance of simCode: some other stuff during SimCode phase: time 0.005242/12.3, allocations: 3.026 MB / 3.875 GB, free: 56.67 MB / 1.042 GB Notification: Performance of simCode: alias equations: time 0.01332/12.31, allocations: 1.693 MB / 3.876 GB, free: 56.6 MB / 1.042 GB Notification: Performance of simCode: all other stuff during SimCode phase: time 0.005095/12.32, allocations: 2.374 MB / 3.879 GB, free: 56.6 MB / 1.042 GB Notification: Performance of SimCode: time 1.162e-06/12.32, allocations: 0 / 3.879 GB, free: 56.6 MB / 1.042 GB Notification: Performance of buildModelFMU: Generate the FMI files: time 0.3646/12.68, allocations: 178.3 MB / 4.053 GB, free: 42.3 MB / 1.042 GB Notification: Performance of buildModelFMU: configured platform static using cached values: time 0.0002906/12.68, allocations: 163.4 kB / 4.053 GB, free: 42.11 MB / 1.042 GB Error: Error building simulator. Build log: clang -Os -fPIC -falign-functions -mfpmath=sse -DOMC_MINIMAL_RUNTIME=1 -DCMINPACK_NO_DLL=1 -Iinclude/ -Iinclude/fmi2 -I. "-I/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Resources/C-Sources" -DOMC_MODEL_PREFIX=AixLib_AixLib_Systems_HydraulicModules_Example_Pump -DOMC_NUM_MIXED_SYSTEMS=0 -DOMC_NUM_LINEAR_SYSTEMS=10 -DOMC_NUM_NONLINEAR_SYSTEMS=11 -DOMC_NDELAY_EXPRESSIONS=0 -DOMC_NVAR_STRING=0 -c -o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_FMU.o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_FMU.c In file included from AixLib_AixLib_Systems_HydraulicModules_Example_Pump_FMU.c:9: In file included from include/openmodelica.h:69: In file included from include/openmodelica_types.h:110: include/gc/omc_gc.h:217:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ include/gc/omc_gc.h:221:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ In file included from AixLib_AixLib_Systems_HydraulicModules_Example_Pump_FMU.c:54: include/fmi2/fmu2_model_interface.c:73:11: warning: enumeration value 'modelSlaveInitialized' not handled in switch [-Wswitch] switch (comp->state) ^ include/fmi2/fmu2_model_interface.c:162:16: warning: passing 'char **' to parameter of type 'const char **' discards qualifiers in nested pointer types [-Wincompatible-pointer-types-discards-qualifiers] GC_vasprintf(&str, msg, args); ^~~~ include/util/modelica_string.h:71:31: note: passing argument to parameter 'strp' here int GC_vasprintf(const char **strp, const char *fmt, va_list ap); ^ 4 warnings generated. clang -Os -fPIC -falign-functions -mfpmath=sse -DOMC_MINIMAL_RUNTIME=1 -DCMINPACK_NO_DLL=1 -Iinclude/ -Iinclude/fmi2 -I. "-I/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Resources/C-Sources" -DOMC_MODEL_PREFIX=AixLib_AixLib_Systems_HydraulicModules_Example_Pump -DOMC_NUM_MIXED_SYSTEMS=0 -DOMC_NUM_LINEAR_SYSTEMS=10 -DOMC_NUM_NONLINEAR_SYSTEMS=11 -DOMC_NDELAY_EXPRESSIONS=0 -DOMC_NVAR_STRING=0 -c -o AixLib_AixLib_Systems_HydraulicModules_Example_Pump.o AixLib_AixLib_Systems_HydraulicModules_Example_Pump.c In file included from AixLib_AixLib_Systems_HydraulicModules_Example_Pump.c:7: In file included from ./AixLib_AixLib_Systems_HydraulicModules_Example_Pump_model.h:5: In file included from include/openmodelica.h:69: In file included from include/openmodelica_types.h:110: include/gc/omc_gc.h:217:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ include/gc/omc_gc.h:221:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ AixLib_AixLib_Systems_HydraulicModules_Example_Pump.c:1192:101: warning: implicit declaration of function 'spatialDistribution' is invalid in C99 [-Wimplicit-function-declaration] data->localData[0]->realVars[349] /* Unmixed.pipe3.plugFlowPipe.timDel.time_out_rev variable */ = spatialDistribution(data->localData[0]->timeValue, data->localData[0]->timeValue, data->localData[0]->realVars[19] /* Unmixed.pipe3.plugFlowPipe.timDel.x STATE(1,Unmixed.pipe3.plugFlowPipe.timDel.u) */, tmp18, tmp19, tmp20 ,&data->localData[0]->realVars[348] /* Unmixed.pipe3.plugFlowPipe.timDel.time_out_des variable */); ^ AixLib_AixLib_Systems_HydraulicModules_Example_Pump.c:1307:101: warning: implicit declaration of function 'spatialDistribution' is invalid in C99 [-Wimplicit-function-declaration] data->localData[0]->realVars[287] /* Unmixed.pipe2.plugFlowPipe.timDel.time_out_rev variable */ = spatialDistribution(data->localData[0]->timeValue, data->localData[0]->timeValue, data->localData[0]->realVars[14] /* Unmixed.pipe2.plugFlowPipe.timDel.x STATE(1,Unmixed.pipe2.plugFlowPipe.timDel.u) */, tmp21, tmp22, tmp23 ,&data->localData[0]->realVars[286] /* Unmixed.pipe2.plugFlowPipe.timDel.time_out_des variable */); ^ AixLib_AixLib_Systems_HydraulicModules_Example_Pump.c:1410:101: warning: implicit declaration of function 'spatialDistribution' is invalid in C99 [-Wimplicit-function-declaration] data->localData[0]->realVars[226] /* Unmixed.pipe1.plugFlowPipe.timDel.time_out_rev variable */ = spatialDistribution(data->localData[0]->timeValue, data->localData[0]->timeValue, data->localData[0]->realVars[9] /* Unmixed.pipe1.plugFlowPipe.timDel.x STATE(1,Unmixed.pipe1.plugFlowPipe.timDel.u) */, tmp24, tmp25, tmp26 ,&data->localData[0]->realVars[225] /* Unmixed.pipe1.plugFlowPipe.timDel.time_out_des variable */); ^ AixLib_AixLib_Systems_HydraulicModules_Example_Pump.c:1657:102: warning: implicit declaration of function 'spatialDistribution' is invalid in C99 [-Wimplicit-function-declaration] data->localData[0]->realVars[346] /* Unmixed.pipe3.plugFlowPipe.res.port_a.h_outflow variable */ = spatialDistribution(data->localData[0]->realVars[385] /* Unmixed.port_a2.h_outflow variable */, data->localData[0]->realVars[389] /* Unmixed.port_b2.h_outflow variable */, (0.5) * (data->localData[0]->realVars[18] /* Unmixed.pipe3.plugFlowPipe.del.x STATE(1,Unmixed.pipe3.plugFlowPipe.v) */), tmp27, tmp28, tmp29 ,&data->localData[0]->realVars[331] /* Unmixed.pipe3.plugFlowPipe.del.port_b.h_outflow variable */); ^ AixLib_AixLib_Systems_HydraulicModules_Example_Pump.c:1784:102: warning: implicit declaration of function 'spatialDistribution' is invalid in C99 [-Wimplicit-function-declaration] data->localData[0]->realVars[223] /* Unmixed.pipe1.plugFlowPipe.res.port_a.h_outflow variable */ = spatialDistribution(data->localData[0]->realVars[384] /* Unmixed.port_a1.h_outflow variable */, data->localData[0]->realVars[261] /* Unmixed.pipe1.port_b.h_outflow variable */, data->localData[0]->realVars[8] /* Unmixed.pipe1.plugFlowPipe.del.x STATE(1,Unmixed.pipe1.plugFlowPipe.v) */, tmp34, tmp35, tmp36 ,&data->localData[0]->realVars[208] /* Unmixed.pipe1.plugFlowPipe.del.port_b.h_outflow variable */); ^ AixLib_AixLib_Systems_HydraulicModules_Example_Pump.c:1935:102: warning: implicit declaration of function 'spatialDistribution' is invalid in C99 [-Wimplicit-function-declaration] data->localData[0]->realVars[284] /* Unmixed.pipe2.plugFlowPipe.res.port_a.h_outflow variable */ = spatialDistribution(data->localData[0]->realVars[322] /* Unmixed.pipe2.port_a.h_outflow variable */, data->localData[0]->realVars[387] /* Unmixed.port_b1.h_outflow variable */, data->localData[0]->realVars[13] /* Unmixed.pipe2.plugFlowPipe.del.x STATE(1,Unmixed.pipe2.plugFlowPipe.v) */, tmp41, tmp42, tmp43 ,&data->localData[0]->realVars[270] /* Unmixed.pipe2.plugFlowPipe.del.port_b.h_outflow variable */); ^ 8 warnings generated. clang -Os -fPIC -falign-functions -mfpmath=sse -DOMC_MINIMAL_RUNTIME=1 -DCMINPACK_NO_DLL=1 -Iinclude/ -Iinclude/fmi2 -I. "-I/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Resources/C-Sources" -DOMC_MODEL_PREFIX=AixLib_AixLib_Systems_HydraulicModules_Example_Pump -DOMC_NUM_MIXED_SYSTEMS=0 -DOMC_NUM_LINEAR_SYSTEMS=10 -DOMC_NUM_NONLINEAR_SYSTEMS=11 -DOMC_NDELAY_EXPRESSIONS=0 -DOMC_NVAR_STRING=0 -c -o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_functions.o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_functions.c In file included from AixLib_AixLib_Systems_HydraulicModules_Example_Pump_functions.c:1: In file included from ./AixLib_AixLib_Systems_HydraulicModules_Example_Pump_functions.h:3: In file included from include/meta/meta_modelica.h:49: include/gc/omc_gc.h:217:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ include/gc/omc_gc.h:221:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -falign-functions -mfpmath=sse -DOMC_MINIMAL_RUNTIME=1 -DCMINPACK_NO_DLL=1 -Iinclude/ -Iinclude/fmi2 -I. "-I/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Resources/C-Sources" -DOMC_MODEL_PREFIX=AixLib_AixLib_Systems_HydraulicModules_Example_Pump -DOMC_NUM_MIXED_SYSTEMS=0 -DOMC_NUM_LINEAR_SYSTEMS=10 -DOMC_NUM_NONLINEAR_SYSTEMS=11 -DOMC_NDELAY_EXPRESSIONS=0 -DOMC_NVAR_STRING=0 -c -o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_records.o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_records.c In file included from AixLib_AixLib_Systems_HydraulicModules_Example_Pump_records.c:3: In file included from include/meta/meta_modelica.h:49: include/gc/omc_gc.h:217:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ include/gc/omc_gc.h:221:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -falign-functions -mfpmath=sse -DOMC_MINIMAL_RUNTIME=1 -DCMINPACK_NO_DLL=1 -Iinclude/ -Iinclude/fmi2 -I. "-I/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Resources/C-Sources" -DOMC_MODEL_PREFIX=AixLib_AixLib_Systems_HydraulicModules_Example_Pump -DOMC_NUM_MIXED_SYSTEMS=0 -DOMC_NUM_LINEAR_SYSTEMS=10 -DOMC_NUM_NONLINEAR_SYSTEMS=11 -DOMC_NDELAY_EXPRESSIONS=0 -DOMC_NVAR_STRING=0 -c -o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_01exo.o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_01exo.c In file included from AixLib_AixLib_Systems_HydraulicModules_Example_Pump_01exo.c:2: In file included from ./AixLib_AixLib_Systems_HydraulicModules_Example_Pump_model.h:5: In file included from include/openmodelica.h:69: In file included from include/openmodelica_types.h:110: include/gc/omc_gc.h:217:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ include/gc/omc_gc.h:221:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -falign-functions -mfpmath=sse -DOMC_MINIMAL_RUNTIME=1 -DCMINPACK_NO_DLL=1 -Iinclude/ -Iinclude/fmi2 -I. "-I/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Resources/C-Sources" -DOMC_MODEL_PREFIX=AixLib_AixLib_Systems_HydraulicModules_Example_Pump -DOMC_NUM_MIXED_SYSTEMS=0 -DOMC_NUM_LINEAR_SYSTEMS=10 -DOMC_NUM_NONLINEAR_SYSTEMS=11 -DOMC_NDELAY_EXPRESSIONS=0 -DOMC_NVAR_STRING=0 -c -o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_02nls.o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_02nls.c In file included from AixLib_AixLib_Systems_HydraulicModules_Example_Pump_02nls.c:2: In file included from ./AixLib_AixLib_Systems_HydraulicModules_Example_Pump_model.h:5: In file included from include/openmodelica.h:69: In file included from include/openmodelica_types.h:110: include/gc/omc_gc.h:217:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ include/gc/omc_gc.h:221:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -falign-functions -mfpmath=sse -DOMC_MINIMAL_RUNTIME=1 -DCMINPACK_NO_DLL=1 -Iinclude/ -Iinclude/fmi2 -I. "-I/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Resources/C-Sources" -DOMC_MODEL_PREFIX=AixLib_AixLib_Systems_HydraulicModules_Example_Pump -DOMC_NUM_MIXED_SYSTEMS=0 -DOMC_NUM_LINEAR_SYSTEMS=10 -DOMC_NUM_NONLINEAR_SYSTEMS=11 -DOMC_NDELAY_EXPRESSIONS=0 -DOMC_NVAR_STRING=0 -c -o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_03lsy.o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_03lsy.c In file included from AixLib_AixLib_Systems_HydraulicModules_Example_Pump_03lsy.c:2: In file included from ./AixLib_AixLib_Systems_HydraulicModules_Example_Pump_model.h:5: In file included from include/openmodelica.h:69: In file included from include/openmodelica_types.h:110: include/gc/omc_gc.h:217:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ include/gc/omc_gc.h:221:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -falign-functions -mfpmath=sse -DOMC_MINIMAL_RUNTIME=1 -DCMINPACK_NO_DLL=1 -Iinclude/ -Iinclude/fmi2 -I. "-I/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Resources/C-Sources" -DOMC_MODEL_PREFIX=AixLib_AixLib_Systems_HydraulicModules_Example_Pump -DOMC_NUM_MIXED_SYSTEMS=0 -DOMC_NUM_LINEAR_SYSTEMS=10 -DOMC_NUM_NONLINEAR_SYSTEMS=11 -DOMC_NDELAY_EXPRESSIONS=0 -DOMC_NVAR_STRING=0 -c -o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_04set.o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_04set.c In file included from AixLib_AixLib_Systems_HydraulicModules_Example_Pump_04set.c:2: In file included from ./AixLib_AixLib_Systems_HydraulicModules_Example_Pump_model.h:5: In file included from include/openmodelica.h:69: In file included from include/openmodelica_types.h:110: include/gc/omc_gc.h:217:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ include/gc/omc_gc.h:221:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -falign-functions -mfpmath=sse -DOMC_MINIMAL_RUNTIME=1 -DCMINPACK_NO_DLL=1 -Iinclude/ -Iinclude/fmi2 -I. "-I/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Resources/C-Sources" -DOMC_MODEL_PREFIX=AixLib_AixLib_Systems_HydraulicModules_Example_Pump -DOMC_NUM_MIXED_SYSTEMS=0 -DOMC_NUM_LINEAR_SYSTEMS=10 -DOMC_NUM_NONLINEAR_SYSTEMS=11 -DOMC_NDELAY_EXPRESSIONS=0 -DOMC_NVAR_STRING=0 -c -o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_05evt.o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_05evt.c In file included from AixLib_AixLib_Systems_HydraulicModules_Example_Pump_05evt.c:2: In file included from ./AixLib_AixLib_Systems_HydraulicModules_Example_Pump_model.h:5: In file included from include/openmodelica.h:69: In file included from include/openmodelica_types.h:110: include/gc/omc_gc.h:217:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ include/gc/omc_gc.h:221:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -falign-functions -mfpmath=sse -DOMC_MINIMAL_RUNTIME=1 -DCMINPACK_NO_DLL=1 -Iinclude/ -Iinclude/fmi2 -I. "-I/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Resources/C-Sources" -DOMC_MODEL_PREFIX=AixLib_AixLib_Systems_HydraulicModules_Example_Pump -DOMC_NUM_MIXED_SYSTEMS=0 -DOMC_NUM_LINEAR_SYSTEMS=10 -DOMC_NUM_NONLINEAR_SYSTEMS=11 -DOMC_NDELAY_EXPRESSIONS=0 -DOMC_NVAR_STRING=0 -c -o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_06inz.o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_06inz.c In file included from AixLib_AixLib_Systems_HydraulicModules_Example_Pump_06inz.c:2: In file included from ./AixLib_AixLib_Systems_HydraulicModules_Example_Pump_model.h:5: In file included from include/openmodelica.h:69: In file included from include/openmodelica_types.h:110: include/gc/omc_gc.h:217:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ include/gc/omc_gc.h:221:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ AixLib_AixLib_Systems_HydraulicModules_Example_Pump_06inz.c:1552:102: warning: implicit declaration of function 'spatialDistribution' is invalid in C99 [-Wimplicit-function-declaration] data->localData[0]->realVars[223] /* Unmixed.pipe1.plugFlowPipe.res.port_a.h_outflow variable */ = spatialDistribution(data->localData[0]->realVars[384] /* Unmixed.port_a1.h_outflow variable */, data->localData[0]->realVars[261] /* Unmixed.pipe1.port_b.h_outflow variable */, data->localData[0]->realVars[8] /* Unmixed.pipe1.plugFlowPipe.del.x STATE(1,Unmixed.pipe1.plugFlowPipe.v) */, tmp0, tmp1, tmp2 ,&data->localData[0]->realVars[208] /* Unmixed.pipe1.plugFlowPipe.del.port_b.h_outflow variable */); ^ AixLib_AixLib_Systems_HydraulicModules_Example_Pump_06inz.c:1602:101: warning: implicit declaration of function 'spatialDistribution' is invalid in C99 [-Wimplicit-function-declaration] data->localData[0]->realVars[226] /* Unmixed.pipe1.plugFlowPipe.timDel.time_out_rev variable */ = spatialDistribution(data->localData[0]->timeValue, data->localData[0]->timeValue, data->localData[0]->realVars[9] /* Unmixed.pipe1.plugFlowPipe.timDel.x STATE(1,Unmixed.pipe1.plugFlowPipe.timDel.u) */, tmp3, tmp4, tmp5 ,&data->localData[0]->realVars[225] /* Unmixed.pipe1.plugFlowPipe.timDel.time_out_des variable */); ^ AixLib_AixLib_Systems_HydraulicModules_Example_Pump_06inz.c:1722:101: warning: implicit declaration of function 'spatialDistribution' is invalid in C99 [-Wimplicit-function-declaration] data->localData[0]->realVars[287] /* Unmixed.pipe2.plugFlowPipe.timDel.time_out_rev variable */ = spatialDistribution(data->localData[0]->timeValue, data->localData[0]->timeValue, data->localData[0]->realVars[14] /* Unmixed.pipe2.plugFlowPipe.timDel.x STATE(1,Unmixed.pipe2.plugFlowPipe.timDel.u) */, tmp0, tmp1, tmp2 ,&data->localData[0]->realVars[286] /* Unmixed.pipe2.plugFlowPipe.timDel.time_out_des variable */); ^ AixLib_AixLib_Systems_HydraulicModules_Example_Pump_06inz.c:1812:102: warning: implicit declaration of function 'spatialDistribution' is invalid in C99 [-Wimplicit-function-declaration] data->localData[0]->realVars[346] /* Unmixed.pipe3.plugFlowPipe.res.port_a.h_outflow variable */ = spatialDistribution(data->localData[0]->realVars[385] /* Unmixed.port_a2.h_outflow variable */, data->localData[0]->realVars[389] /* Unmixed.port_b2.h_outflow variable */, (0.5) * (data->localData[0]->realVars[18] /* Unmixed.pipe3.plugFlowPipe.del.x STATE(1,Unmixed.pipe3.plugFlowPipe.v) */), tmp3, tmp4, tmp5 ,&data->localData[0]->realVars[331] /* Unmixed.pipe3.plugFlowPipe.del.port_b.h_outflow variable */); ^ AixLib_AixLib_Systems_HydraulicModules_Example_Pump_06inz.c:1862:101: warning: implicit declaration of function 'spatialDistribution' is invalid in C99 [-Wimplicit-function-declaration] data->localData[0]->realVars[349] /* Unmixed.pipe3.plugFlowPipe.timDel.time_out_rev variable */ = spatialDistribution(data->localData[0]->timeValue, data->localData[0]->timeValue, data->localData[0]->realVars[19] /* Unmixed.pipe3.plugFlowPipe.timDel.x STATE(1,Unmixed.pipe3.plugFlowPipe.timDel.u) */, tmp6, tmp7, tmp8 ,&data->localData[0]->realVars[348] /* Unmixed.pipe3.plugFlowPipe.timDel.time_out_des variable */); ^ AixLib_AixLib_Systems_HydraulicModules_Example_Pump_06inz.c:2048:102: warning: implicit declaration of function 'spatialDistribution' is invalid in C99 [-Wimplicit-function-declaration] data->localData[0]->realVars[284] /* Unmixed.pipe2.plugFlowPipe.res.port_a.h_outflow variable */ = spatialDistribution(data->localData[0]->realVars[322] /* Unmixed.pipe2.port_a.h_outflow variable */, data->localData[0]->realVars[387] /* Unmixed.port_b1.h_outflow variable */, data->localData[0]->realVars[13] /* Unmixed.pipe2.plugFlowPipe.del.x STATE(1,Unmixed.pipe2.plugFlowPipe.v) */, tmp0, tmp1, tmp2 ,&data->localData[0]->realVars[270] /* Unmixed.pipe2.plugFlowPipe.del.port_b.h_outflow variable */); ^ AixLib_AixLib_Systems_HydraulicModules_Example_Pump_06inz.c:20980:102: warning: implicit declaration of function 'spatialDistribution' is invalid in C99 [-Wimplicit-function-declaration] data->localData[0]->realVars[223] /* Unmixed.pipe1.plugFlowPipe.res.port_a.h_outflow variable */ = spatialDistribution(data->localData[0]->realVars[384] /* Unmixed.port_a1.h_outflow variable */, data->localData[0]->realVars[261] /* Unmixed.pipe1.port_b.h_outflow variable */, data->localData[0]->realVars[8] /* Unmixed.pipe1.plugFlowPipe.del.x STATE(1,Unmixed.pipe1.plugFlowPipe.v) */, tmp75, tmp76, tmp77 ,&data->localData[0]->realVars[208] /* Unmixed.pipe1.plugFlowPipe.del.port_b.h_outflow variable */); ^ AixLib_AixLib_Systems_HydraulicModules_Example_Pump_06inz.c:21008:101: warning: implicit declaration of function 'spatialDistribution' is invalid in C99 [-Wimplicit-function-declaration] data->localData[0]->realVars[226] /* Unmixed.pipe1.plugFlowPipe.timDel.time_out_rev variable */ = spatialDistribution(data->localData[0]->timeValue, data->localData[0]->timeValue, data->localData[0]->realVars[9] /* Unmixed.pipe1.plugFlowPipe.timDel.x STATE(1,Unmixed.pipe1.plugFlowPipe.timDel.u) */, tmp78, tmp79, tmp80 ,&data->localData[0]->realVars[225] /* Unmixed.pipe1.plugFlowPipe.timDel.time_out_des variable */); ^ AixLib_AixLib_Systems_HydraulicModules_Example_Pump_06inz.c:21095:101: warning: implicit declaration of function 'spatialDistribution' is invalid in C99 [-Wimplicit-function-declaration] data->localData[0]->realVars[287] /* Unmixed.pipe2.plugFlowPipe.timDel.time_out_rev variable */ = spatialDistribution(data->localData[0]->timeValue, data->localData[0]->timeValue, data->localData[0]->realVars[14] /* Unmixed.pipe2.plugFlowPipe.timDel.x STATE(1,Unmixed.pipe2.plugFlowPipe.timDel.u) */, tmp0, tmp1, tmp2 ,&data->localData[0]->realVars[286] /* Unmixed.pipe2.plugFlowPipe.timDel.time_out_des variable */); ^ AixLib_AixLib_Systems_HydraulicModules_Example_Pump_06inz.c:21141:102: warning: implicit declaration of function 'spatialDistribution' is invalid in C99 [-Wimplicit-function-declaration] data->localData[0]->realVars[346] /* Unmixed.pipe3.plugFlowPipe.res.port_a.h_outflow variable */ = spatialDistribution(data->localData[0]->realVars[385] /* Unmixed.port_a2.h_outflow variable */, data->localData[0]->realVars[389] /* Unmixed.port_b2.h_outflow variable */, (0.5) * (data->localData[0]->realVars[18] /* Unmixed.pipe3.plugFlowPipe.del.x STATE(1,Unmixed.pipe3.plugFlowPipe.v) */), tmp3, tmp4, tmp5 ,&data->localData[0]->realVars[331] /* Unmixed.pipe3.plugFlowPipe.del.port_b.h_outflow variable */); ^ AixLib_AixLib_Systems_HydraulicModules_Example_Pump_06inz.c:21169:101: warning: implicit declaration of function 'spatialDistribution' is invalid in C99 [-Wimplicit-function-declaration] data->localData[0]->realVars[349] /* Unmixed.pipe3.plugFlowPipe.timDel.time_out_rev variable */ = spatialDistribution(data->localData[0]->timeValue, data->localData[0]->timeValue, data->localData[0]->realVars[19] /* Unmixed.pipe3.plugFlowPipe.timDel.x STATE(1,Unmixed.pipe3.plugFlowPipe.timDel.u) */, tmp6, tmp7, tmp8 ,&data->localData[0]->realVars[348] /* Unmixed.pipe3.plugFlowPipe.timDel.time_out_des variable */); ^ AixLib_AixLib_Systems_HydraulicModules_Example_Pump_06inz.c:21278:102: warning: implicit declaration of function 'spatialDistribution' is invalid in C99 [-Wimplicit-function-declaration] data->localData[0]->realVars[284] /* Unmixed.pipe2.plugFlowPipe.res.port_a.h_outflow variable */ = spatialDistribution(data->localData[0]->realVars[322] /* Unmixed.pipe2.port_a.h_outflow variable */, data->localData[0]->realVars[387] /* Unmixed.port_b1.h_outflow variable */, data->localData[0]->realVars[13] /* Unmixed.pipe2.plugFlowPipe.del.x STATE(1,Unmixed.pipe2.plugFlowPipe.v) */, tmp0, tmp1, tmp2 ,&data->localData[0]->realVars[270] /* Unmixed.pipe2.plugFlowPipe.del.port_b.h_outflow variable */); ^ 14 warnings generated. clang -Os -fPIC -falign-functions -mfpmath=sse -DOMC_MINIMAL_RUNTIME=1 -DCMINPACK_NO_DLL=1 -Iinclude/ -Iinclude/fmi2 -I. "-I/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Resources/C-Sources" -DOMC_MODEL_PREFIX=AixLib_AixLib_Systems_HydraulicModules_Example_Pump -DOMC_NUM_MIXED_SYSTEMS=0 -DOMC_NUM_LINEAR_SYSTEMS=10 -DOMC_NUM_NONLINEAR_SYSTEMS=11 -DOMC_NDELAY_EXPRESSIONS=0 -DOMC_NVAR_STRING=0 -c -o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_07dly.o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_07dly.c In file included from AixLib_AixLib_Systems_HydraulicModules_Example_Pump_07dly.c:2: In file included from ./AixLib_AixLib_Systems_HydraulicModules_Example_Pump_model.h:5: In file included from include/openmodelica.h:69: In file included from include/openmodelica_types.h:110: include/gc/omc_gc.h:217:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ include/gc/omc_gc.h:221:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -falign-functions -mfpmath=sse -DOMC_MINIMAL_RUNTIME=1 -DCMINPACK_NO_DLL=1 -Iinclude/ -Iinclude/fmi2 -I. "-I/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Resources/C-Sources" -DOMC_MODEL_PREFIX=AixLib_AixLib_Systems_HydraulicModules_Example_Pump -DOMC_NUM_MIXED_SYSTEMS=0 -DOMC_NUM_LINEAR_SYSTEMS=10 -DOMC_NUM_NONLINEAR_SYSTEMS=11 -DOMC_NDELAY_EXPRESSIONS=0 -DOMC_NVAR_STRING=0 -c -o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_08bnd.o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_08bnd.c In file included from AixLib_AixLib_Systems_HydraulicModules_Example_Pump_08bnd.c:2: In file included from ./AixLib_AixLib_Systems_HydraulicModules_Example_Pump_model.h:5: In file included from include/openmodelica.h:69: In file included from include/openmodelica_types.h:110: include/gc/omc_gc.h:217:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ include/gc/omc_gc.h:221:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -falign-functions -mfpmath=sse -DOMC_MINIMAL_RUNTIME=1 -DCMINPACK_NO_DLL=1 -Iinclude/ -Iinclude/fmi2 -I. "-I/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Resources/C-Sources" -DOMC_MODEL_PREFIX=AixLib_AixLib_Systems_HydraulicModules_Example_Pump -DOMC_NUM_MIXED_SYSTEMS=0 -DOMC_NUM_LINEAR_SYSTEMS=10 -DOMC_NUM_NONLINEAR_SYSTEMS=11 -DOMC_NDELAY_EXPRESSIONS=0 -DOMC_NVAR_STRING=0 -c -o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_09alg.o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_09alg.c In file included from AixLib_AixLib_Systems_HydraulicModules_Example_Pump_09alg.c:2: In file included from ./AixLib_AixLib_Systems_HydraulicModules_Example_Pump_model.h:5: In file included from include/openmodelica.h:69: In file included from include/openmodelica_types.h:110: include/gc/omc_gc.h:217:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ include/gc/omc_gc.h:221:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -falign-functions -mfpmath=sse -DOMC_MINIMAL_RUNTIME=1 -DCMINPACK_NO_DLL=1 -Iinclude/ -Iinclude/fmi2 -I. "-I/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Resources/C-Sources" -DOMC_MODEL_PREFIX=AixLib_AixLib_Systems_HydraulicModules_Example_Pump -DOMC_NUM_MIXED_SYSTEMS=0 -DOMC_NUM_LINEAR_SYSTEMS=10 -DOMC_NUM_NONLINEAR_SYSTEMS=11 -DOMC_NDELAY_EXPRESSIONS=0 -DOMC_NVAR_STRING=0 -c -o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_10asr.o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_10asr.c In file included from AixLib_AixLib_Systems_HydraulicModules_Example_Pump_10asr.c:2: In file included from ./AixLib_AixLib_Systems_HydraulicModules_Example_Pump_model.h:5: In file included from include/openmodelica.h:69: In file included from include/openmodelica_types.h:110: include/gc/omc_gc.h:217:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ include/gc/omc_gc.h:221:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -falign-functions -mfpmath=sse -DOMC_MINIMAL_RUNTIME=1 -DCMINPACK_NO_DLL=1 -Iinclude/ -Iinclude/fmi2 -I. "-I/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Resources/C-Sources" -DOMC_MODEL_PREFIX=AixLib_AixLib_Systems_HydraulicModules_Example_Pump -DOMC_NUM_MIXED_SYSTEMS=0 -DOMC_NUM_LINEAR_SYSTEMS=10 -DOMC_NUM_NONLINEAR_SYSTEMS=11 -DOMC_NDELAY_EXPRESSIONS=0 -DOMC_NVAR_STRING=0 -c -o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_11mix.o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_11mix.c In file included from AixLib_AixLib_Systems_HydraulicModules_Example_Pump_11mix.c:2: In file included from ./AixLib_AixLib_Systems_HydraulicModules_Example_Pump_model.h:5: In file included from include/openmodelica.h:69: In file included from include/openmodelica_types.h:110: include/gc/omc_gc.h:217:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ include/gc/omc_gc.h:221:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -falign-functions -mfpmath=sse -DOMC_MINIMAL_RUNTIME=1 -DCMINPACK_NO_DLL=1 -Iinclude/ -Iinclude/fmi2 -I. "-I/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Resources/C-Sources" -DOMC_MODEL_PREFIX=AixLib_AixLib_Systems_HydraulicModules_Example_Pump -DOMC_NUM_MIXED_SYSTEMS=0 -DOMC_NUM_LINEAR_SYSTEMS=10 -DOMC_NUM_NONLINEAR_SYSTEMS=11 -DOMC_NDELAY_EXPRESSIONS=0 -DOMC_NVAR_STRING=0 -c -o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_12jac.o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_12jac.c In file included from AixLib_AixLib_Systems_HydraulicModules_Example_Pump_12jac.c:2: In file included from ./AixLib_AixLib_Systems_HydraulicModules_Example_Pump_model.h:5: In file included from include/openmodelica.h:69: In file included from include/openmodelica_types.h:110: include/gc/omc_gc.h:217:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ include/gc/omc_gc.h:221:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -falign-functions -mfpmath=sse -DOMC_MINIMAL_RUNTIME=1 -DCMINPACK_NO_DLL=1 -Iinclude/ -Iinclude/fmi2 -I. "-I/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Resources/C-Sources" -DOMC_MODEL_PREFIX=AixLib_AixLib_Systems_HydraulicModules_Example_Pump -DOMC_NUM_MIXED_SYSTEMS=0 -DOMC_NUM_LINEAR_SYSTEMS=10 -DOMC_NUM_NONLINEAR_SYSTEMS=11 -DOMC_NDELAY_EXPRESSIONS=0 -DOMC_NVAR_STRING=0 -c -o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_13opt.o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_13opt.c In file included from AixLib_AixLib_Systems_HydraulicModules_Example_Pump_13opt.c:2: In file included from ./AixLib_AixLib_Systems_HydraulicModules_Example_Pump_model.h:5: In file included from include/openmodelica.h:69: In file included from include/openmodelica_types.h:110: include/gc/omc_gc.h:217:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ include/gc/omc_gc.h:221:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -falign-functions -mfpmath=sse -DOMC_MINIMAL_RUNTIME=1 -DCMINPACK_NO_DLL=1 -Iinclude/ -Iinclude/fmi2 -I. "-I/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Resources/C-Sources" -DOMC_MODEL_PREFIX=AixLib_AixLib_Systems_HydraulicModules_Example_Pump -DOMC_NUM_MIXED_SYSTEMS=0 -DOMC_NUM_LINEAR_SYSTEMS=10 -DOMC_NUM_NONLINEAR_SYSTEMS=11 -DOMC_NDELAY_EXPRESSIONS=0 -DOMC_NVAR_STRING=0 -c -o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_14lnz.o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_14lnz.c In file included from AixLib_AixLib_Systems_HydraulicModules_Example_Pump_14lnz.c:2: In file included from ./AixLib_AixLib_Systems_HydraulicModules_Example_Pump_model.h:5: In file included from include/openmodelica.h:69: In file included from include/openmodelica_types.h:110: include/gc/omc_gc.h:217:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ include/gc/omc_gc.h:221:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -falign-functions -mfpmath=sse -DOMC_MINIMAL_RUNTIME=1 -DCMINPACK_NO_DLL=1 -Iinclude/ -Iinclude/fmi2 -I. "-I/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Resources/C-Sources" -DOMC_MODEL_PREFIX=AixLib_AixLib_Systems_HydraulicModules_Example_Pump -DOMC_NUM_MIXED_SYSTEMS=0 -DOMC_NUM_LINEAR_SYSTEMS=10 -DOMC_NUM_NONLINEAR_SYSTEMS=11 -DOMC_NDELAY_EXPRESSIONS=0 -DOMC_NVAR_STRING=0 -c -o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_15syn.o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_15syn.c In file included from AixLib_AixLib_Systems_HydraulicModules_Example_Pump_15syn.c:2: In file included from ./AixLib_AixLib_Systems_HydraulicModules_Example_Pump_model.h:5: In file included from include/openmodelica.h:69: In file included from include/openmodelica_types.h:110: include/gc/omc_gc.h:217:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ include/gc/omc_gc.h:221:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -falign-functions -mfpmath=sse -DOMC_MINIMAL_RUNTIME=1 -DCMINPACK_NO_DLL=1 -Iinclude/ -Iinclude/fmi2 -I. "-I/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Resources/C-Sources" -DOMC_MODEL_PREFIX=AixLib_AixLib_Systems_HydraulicModules_Example_Pump -DOMC_NUM_MIXED_SYSTEMS=0 -DOMC_NUM_LINEAR_SYSTEMS=10 -DOMC_NUM_NONLINEAR_SYSTEMS=11 -DOMC_NDELAY_EXPRESSIONS=0 -DOMC_NVAR_STRING=0 -c -o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_16dae.o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_16dae.c In file included from AixLib_AixLib_Systems_HydraulicModules_Example_Pump_16dae.c:2: In file included from ./AixLib_AixLib_Systems_HydraulicModules_Example_Pump_model.h:5: In file included from include/openmodelica.h:69: In file included from include/openmodelica_types.h:110: include/gc/omc_gc.h:217:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ include/gc/omc_gc.h:221:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -falign-functions -mfpmath=sse -DOMC_MINIMAL_RUNTIME=1 -DCMINPACK_NO_DLL=1 -Iinclude/ -Iinclude/fmi2 -I. "-I/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Resources/C-Sources" -DOMC_MODEL_PREFIX=AixLib_AixLib_Systems_HydraulicModules_Example_Pump -DOMC_NUM_MIXED_SYSTEMS=0 -DOMC_NUM_LINEAR_SYSTEMS=10 -DOMC_NUM_NONLINEAR_SYSTEMS=11 -DOMC_NDELAY_EXPRESSIONS=0 -DOMC_NVAR_STRING=0 -c -o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_17inl.o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_17inl.c In file included from AixLib_AixLib_Systems_HydraulicModules_Example_Pump_17inl.c:2: In file included from ./AixLib_AixLib_Systems_HydraulicModules_Example_Pump_model.h:5: In file included from include/openmodelica.h:69: In file included from include/openmodelica_types.h:110: include/gc/omc_gc.h:217:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ include/gc/omc_gc.h:221:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -falign-functions -mfpmath=sse -DOMC_MINIMAL_RUNTIME=1 -DCMINPACK_NO_DLL=1 -Iinclude/ -Iinclude/fmi2 -I. "-I/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Resources/C-Sources" -DOMC_MODEL_PREFIX=AixLib_AixLib_Systems_HydraulicModules_Example_Pump -DOMC_NUM_MIXED_SYSTEMS=0 -DOMC_NUM_LINEAR_SYSTEMS=10 -DOMC_NUM_NONLINEAR_SYSTEMS=11 -DOMC_NDELAY_EXPRESSIONS=0 -DOMC_NVAR_STRING=0 -c -o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_init_fmu.o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_init_fmu.c In file included from AixLib_AixLib_Systems_HydraulicModules_Example_Pump_init_fmu.c:1: In file included from include/simulation_data.h:39: In file included from include/openmodelica.h:69: In file included from include/openmodelica_types.h:110: include/gc/omc_gc.h:217:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ include/gc/omc_gc.h:221:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. mkdir -p ../binaries/linux64 clang -shared -o AixLib_AixLib_Systems_HydraulicModules_Example_Pump.so AixLib_AixLib_Systems_HydraulicModules_Example_Pump_FMU.o AixLib_AixLib_Systems_HydraulicModules_Example_Pump.o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_functions.o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_records.o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_01exo.o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_02nls.o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_03lsy.o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_04set.o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_05evt.o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_06inz.o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_07dly.o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_08bnd.o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_09alg.o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_10asr.o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_11mix.o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_12jac.o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_13opt.o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_14lnz.o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_15syn.o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_16dae.o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_17inl.o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_init_fmu.o -L"/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2-development/Systems/HydraulicModules/Example" "-L/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OMCompiler/build/lib/x86_64-linux-gnu/omc" -Wl,-rpath="/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OMCompiler/build/lib/x86_64-linux-gnu/omc" "-L/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OMCompiler/build/lib/" -Wl,-rpath="/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OMCompiler/build/lib/" "-L/home/hudson/saved_omc/libraries/.openmodelica/binaries/Modelica" -Wl,-rpath="/home/hudson/saved_omc/libraries/.openmodelica/binaries/Modelica" "-L/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Resources/Library/x86_64-linux" -Wl,-rpath="/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Resources/Library/x86_64-linux" "-L/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Resources/Library/linux64" -Wl,-rpath="/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Resources/Library/linux64" "-L/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Resources/Library" -Wl,-rpath="/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Resources/Library" -lModelicaExternalC -L'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OMCompiler/build/lib/x86_64-linux-gnu/omc' -Wl,-rpath,'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OMCompiler/build/lib/x86_64-linux-gnu/omc' -lSimulationRuntimeFMI -llapack -lblas -lm -lpthread -rdynamic -Wl,--no-undefined /usr/bin/ld: AixLib_AixLib_Systems_HydraulicModules_Example_Pump.o: in function `AixLib_AixLib_Systems_HydraulicModules_Example_Pump_eqFunction_2110': AixLib_AixLib_Systems_HydraulicModules_Example_Pump.c:(.text+0x2603): undefined reference to `spatialDistribution' /usr/bin/ld: AixLib_AixLib_Systems_HydraulicModules_Example_Pump.o: in function `AixLib_AixLib_Systems_HydraulicModules_Example_Pump_eqFunction_2119': AixLib_AixLib_Systems_HydraulicModules_Example_Pump.c:(.text+0x2c64): undefined reference to `spatialDistribution' /usr/bin/ld: AixLib_AixLib_Systems_HydraulicModules_Example_Pump.o: in function `AixLib_AixLib_Systems_HydraulicModules_Example_Pump_eqFunction_2127': AixLib_AixLib_Systems_HydraulicModules_Example_Pump.c:(.text+0x3280): undefined reference to `spatialDistribution' /usr/bin/ld: AixLib_AixLib_Systems_HydraulicModules_Example_Pump.o: in function `AixLib_AixLib_Systems_HydraulicModules_Example_Pump_eqFunction_2147': AixLib_AixLib_Systems_HydraulicModules_Example_Pump.c:(.text+0x3fff): undefined reference to `spatialDistribution' /usr/bin/ld: AixLib_AixLib_Systems_HydraulicModules_Example_Pump.o: in function `AixLib_AixLib_Systems_HydraulicModules_Example_Pump_eqFunction_2156': AixLib_AixLib_Systems_HydraulicModules_Example_Pump.c:(.text+0x44d6): undefined reference to `spatialDistribution' /usr/bin/ld: AixLib_AixLib_Systems_HydraulicModules_Example_Pump.o:AixLib_AixLib_Systems_HydraulicModules_Example_Pump.c:(.text+0x4bcb): more undefined references to `spatialDistribution' follow clang: error: linker command failed with exit code 1 (use -v to see invocation) make: *** [Makefile:44: nozip] Error 1