ThermoSysPro test using OpenModelica

Total Frontend Backend SimCode Templates Compilation Simulation Verification
135 133 126 126 126 126 100 0

Total time taken: 2:06:19

System info: Intel(R) Core(TM) i7-6900K CPU @ 3.20GHz, 126 GB RAM, Ubuntu 18.04.2 LTS

OpenModelica Version: OMCompiler v1.12.0-v1.12.0.7+ga21325026

Test started: 2019-12-12 15:34:37

Tested Library: 3.2

BuildModel time limit: 660s

Simulation time limit: 480s

Default tolerance: 1e-06

Optimization level: Tool default

Flags:
setCommandLineOptions("-d=nogen");
setCommandLineOptions("-d=initialization");
setCommandLineOptions("-d=backenddaeinfo");
setCommandLineOptions("-d=discreteinfo");
setCommandLineOptions("-d=stateselection");
setCommandLineOptions("-d=execstat");
setMatchingAlgorithm("PFPlusExt");
setIndexReductionMethod("dynamicStateSelection");

Links are provided if getErrorString() or the simulation generates output. The links are coded with red if there were errors, yellow if there were warnings, and normal links if there are only notifications.

ModelVerifiedSimulateTotal buildModelParsingFrontendBackendSimCodeTemplatesCompile
ThermoSysPro.Examples.Book.PowerPlants.CombinedCyclePowerPlant.GasTurbineTrip (sim) 222.0351.182.378.3618.371.685.7117.05
ThermoSysPro.Examples.Book.PowerPlants.CombinedCyclePowerPlant.LoadVariation (sim) 195.1352.082.328.3518.551.745.7317.70
ThermoSysPro.Examples.Book.PowerPlants.ConcentratedSolarPowerPlant_PTSC (sim) 0.3643.172.376.0917.051.843.9514.24
ThermoSysPro.Examples.Book.PowerPlants.SupercriticalPulverizedCoalPowerPlant 0.0013.552.376.097.460.000.000.00
ThermoSysPro.Examples.Book.SimpleExamples.CentrifugalPump.TestCentrifugalPump.Scenario_1 (sim) 0.164.512.371.230.800.020.102.37
ThermoSysPro.Examples.Book.SimpleExamples.CentrifugalPump.TestCentrifugalPump.Scenario_2 (sim) 0.114.572.421.200.800.020.132.42
ThermoSysPro.Examples.Book.SimpleExamples.CentrifugalPump.TestCentrifugalPump.Scenario_3 (sim) 0.579.022.372.922.800.020.462.82
ThermoSysPro.Examples.Book.SimpleExamples.CentrifugalPump.TestCentrifugalPump.Scenario_4 (sim) 0.824.012.371.220.230.020.122.42
ThermoSysPro.Examples.Book.SimpleExamples.CentrifugalPump.TestStaticCentrifugalPump (sim) 0.624.562.371.220.790.020.112.42
ThermoSysPro.Examples.Book.SimpleExamples.HeatExchanger.DynamicWaterHeater.Islanding 0.004.502.374.330.170.000.000.00
ThermoSysPro.Examples.Book.SimpleExamples.HeatExchanger.DynamicWaterHeater.NegativeFlow 0.004.542.424.380.170.000.000.00
ThermoSysPro.Examples.Book.SimpleExamples.HeatExchanger.DynamicWaterHeater.ZeroFlow 0.004.502.374.330.170.000.000.00
ThermoSysPro.Examples.Book.SimpleExamples.HeatExchanger.TestDynamicCondenser (sim) 3.128.622.371.643.430.070.213.27
ThermoSysPro.Examples.Book.SimpleExamples.HeatExchanger.TestDynamicOnePhaseFlowShell (sim) 4.586.472.371.521.370.080.233.27
ThermoSysPro.Examples.Book.SimpleExamples.HeatExchanger.TestDynamicTwoPhaseFlowPipe (sim) 5.139.422.371.822.590.170.574.27
ThermoSysPro.Examples.Book.SimpleExamples.HeatExchanger.TestStaticCondenser (sim) 0.215.722.371.471.420.030.122.67
ThermoSysPro.Examples.Book.SimpleExamples.PressureLoss.TestBend (sim) 0.115.512.421.501.200.020.332.47
ThermoSysPro.Examples.Book.SimpleExamples.PressureLoss.TestCheckValve (sim) 0.115.372.371.471.190.170.132.42
ThermoSysPro.Examples.Book.SimpleExamples.PressureLoss.TestControlValve (sim) 0.115.362.471.491.190.010.242.42
ThermoSysPro.Examples.Book.SimpleExamples.PressureLoss.TestDiaphragm (sim) 0.115.562.321.471.180.020.432.47
ThermoSysPro.Examples.Book.SimpleExamples.PressureLoss.TestDynamicCheckValve (sim) 4.985.462.371.541.180.010.252.47
ThermoSysPro.Examples.Book.SimpleExamples.PressureLoss.TestDynamicReliefValve (sim) 43.219.372.372.962.900.030.622.87
ThermoSysPro.Examples.Book.SimpleExamples.PressureLoss.TestLumpedStraightPipe (sim) 0.877.972.422.822.160.020.102.87
ThermoSysPro.Examples.Book.SimpleExamples.PressureLoss.TestPipePressureLoss (sim) 0.115.362.371.481.180.010.272.42
ThermoSysPro.Examples.Book.SimpleExamples.PressureLoss.TestSwitchValve (sim) 0.318.572.372.882.780.020.122.77
ThermoSysPro.Examples.Book.SimpleExamples.PressureLoss.TestThreeWayValve (sim) 0.825.572.371.501.250.200.112.52
ThermoSysPro.Examples.Book.SimpleExamples.SolarCollector.TestFresnelField (sim) 27.8821.452.373.166.950.821.908.63
ThermoSysPro.Examples.Book.SimpleExamples.SteamTurbine.TestStodolaTurbine (sim) 0.036.522.371.871.780.020.122.72
ThermoSysPro.Examples.Book.SimpleExamples.Volume.TestDynamicDrum (sim) 135.6714.792.373.405.580.200.734.87
ThermoSysPro.Examples.Book.SimpleExamples.Volume.TestMixer3 (sim) 0.315.762.421.511.240.020.472.52
ThermoSysPro.Examples.Book.SimpleExamples.Volume.TestPressurizer (sim) 0.579.522.372.853.650.030.122.87
ThermoSysPro.Examples.Book.SimpleExamples.Volume.TestSplitter3 (sim) 0.215.512.421.521.170.020.282.52
ThermoSysPro.Examples.Book.SimpleExamples.Volume.TestStaticDrum3 (sim) 0.1612.782.373.323.970.170.604.72
ThermoSysPro.Examples.Book.SimpleExamples.Volume.TestSteamDryer (sim) 0.375.222.371.241.380.020.112.47
ThermoSysPro.Examples.Book.SimpleExamples.Volume.TestTank (sim) 1.529.032.322.853.130.030.142.87
ThermoSysPro.Examples.Book.SimpleExamples.Volume.TestVolumeATh (sim) 1.328.422.422.802.690.020.132.77
ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_Load_100_50 (sim) 152.1253.922.589.3020.152.574.5617.34
ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTAC (sim) 236.7253.472.529.2219.441.765.9117.15
ThermoSysPro.Examples.SimpleExamples.TestAirHumidity (sim) 0.065.412.622.180.040.010.063.12
ThermoSysPro.Examples.SimpleExamples.TestBend (sim) 0.116.072.471.551.230.020.452.82
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump (sim) 0.975.763.071.350.900.030.123.37
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump1 (sim) 0.165.512.771.340.910.030.113.12
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump2 (sim) 0.629.833.473.042.980.030.113.67
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump3 (sim) 1.727.973.272.942.020.030.162.82
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump4 (sim) 1.428.072.673.002.100.030.112.82
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump5 (sim) 0.034.662.471.210.800.020.122.52
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump6 (sim) 0.629.112.422.922.900.030.512.77
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump7 (sim) 0.326.472.421.781.790.040.142.72
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump8 (sim) 0.114.462.421.220.800.010.112.32
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump9 (sim) 0.034.562.371.290.800.020.102.37
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump10 (sim) 0.165.762.371.551.470.020.102.62
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump11 (sim) 0.369.112.323.053.160.020.112.77
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump12 (sim) 0.314.612.521.380.610.020.292.32
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump13 (sim) 0.164.562.371.200.840.020.082.42
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPumpWaterSolution (sim) 0.033.062.420.840.050.030.072.07
ThermoSysPro.Examples.SimpleExamples.TestCheckValve (sim) 1.828.882.472.892.830.030.162.97
ThermoSysPro.Examples.SimpleExamples.TestCompressor (sim) 0.068.122.373.091.940.020.142.92
ThermoSysPro.Examples.SimpleExamples.TestControlValve (sim) 0.115.412.371.491.180.010.262.47
ThermoSysPro.Examples.SimpleExamples.TestDiaphragm (sim) 0.115.562.371.491.190.010.402.47
ThermoSysPro.Examples.SimpleExamples.TestDynamicCentrifugalPump (sim) 33.134.612.421.220.800.020.112.47
ThermoSysPro.Examples.SimpleExamples.TestDynamicCentrifugalPump1 (sim) 1.774.622.421.210.800.020.122.47
ThermoSysPro.Examples.SimpleExamples.TestDynamicCentrifugalPump2 (sim) 480.036.022.321.541.630.030.152.67
ThermoSysPro.Examples.SimpleExamples.TestDynamicCheckValve (sim) 4.675.322.371.471.190.020.282.37
ThermoSysPro.Examples.SimpleExamples.TestDynamicDrum (sim) 6.9313.792.373.364.490.390.664.87
ThermoSysPro.Examples.SimpleExamples.TestDynamicDrum1 (sim) 7.2814.642.373.425.480.200.664.87
ThermoSysPro.Examples.SimpleExamples.TestDynamicDrum2 (sim) 44.2113.842.373.384.520.400.664.87
ThermoSysPro.Examples.SimpleExamples.TestDynamicDrum3 (sim) 6.7213.982.373.364.690.390.674.87
ThermoSysPro.Examples.SimpleExamples.TestDynamicDrum_CC (sim) 138.0414.292.373.384.960.400.674.87
ThermoSysPro.Examples.SimpleExamples.TestDynamicOnePhaseFlowPipe (sim) 0.116.422.371.601.350.070.233.17
ThermoSysPro.Examples.SimpleExamples.TestDynamicReliefValve (sim) 1.778.932.372.892.560.030.522.92
ThermoSysPro.Examples.SimpleExamples.TestDynamicTwoPhaseFlowPipe (sim) 0.1614.532.372.464.100.341.306.32
ThermoSysPro.Examples.SimpleExamples.TestDynamicWaterHeating (sim) 24.5123.662.424.279.720.421.737.53
ThermoSysPro.Examples.SimpleExamples.TestDynamicWaterHeating_Islanding 0.004.502.374.330.180.000.000.00
ThermoSysPro.Examples.SimpleExamples.TestDynamicWaterWaterExchanger (sim) 0.825.612.371.461.150.040.152.82
ThermoSysPro.Examples.SimpleExamples.TestFan 0.002.342.371.900.440.000.000.00
ThermoSysPro.Examples.SimpleExamples.TestFan_Pin (sim) 190.645.272.371.890.440.050.322.57
ThermoSysPro.Examples.SimpleExamples.TestFan_Qin 0.002.292.371.880.410.000.000.00
ThermoSysPro.Examples.SimpleExamples.TestFlueGasesJunctions (sim) 0.114.062.371.800.050.010.082.12
ThermoSysPro.Examples.SimpleExamples.TestFlueGasesVolumes (sim) 0.514.462.371.860.120.020.102.37
ThermoSysPro.Examples.SimpleExamples.TestFlueGasesVolumes1 (sim) 0.674.462.371.820.210.030.092.32
ThermoSysPro.Examples.SimpleExamples.TestIdealCheckValve (sim) 1.579.022.372.922.990.030.162.92
ThermoSysPro.Examples.SimpleExamples.TestIdealSwitchValve (sim) 0.218.432.372.842.720.020.132.72
ThermoSysPro.Examples.SimpleExamples.TestInvSingularPressureLoss (sim) 0.065.412.371.471.150.010.412.37
ThermoSysPro.Examples.SimpleExamples.TestJunctions1 (sim) 0.415.612.371.501.400.020.132.57
ThermoSysPro.Examples.SimpleExamples.TestJunctions2 (sim) 0.725.912.421.471.620.030.132.67
ThermoSysPro.Examples.SimpleExamples.TestJunctions3 (sim) 3.229.122.372.892.800.390.122.92
ThermoSysPro.Examples.SimpleExamples.TestJunctions4 (sim) 0.266.212.371.472.110.020.092.52
ThermoSysPro.Examples.SimpleExamples.TestJunctions5 (sim) 2.579.272.322.933.260.030.142.92
ThermoSysPro.Examples.SimpleExamples.TestLoopBreaker (sim) 0.214.462.371.190.770.020.112.37
ThermoSysPro.Examples.SimpleExamples.TestLumpedStraightPipe (sim) 2.327.722.372.762.000.020.122.82
ThermoSysPro.Examples.SimpleExamples.TestMassFlowMultiplier (sim) 0.214.562.371.340.580.020.262.37
ThermoSysPro.Examples.SimpleExamples.TestNTUWaterHeating0 (sim) 1.126.362.321.492.160.020.122.57
ThermoSysPro.Examples.SimpleExamples.TestNTUWaterHeating1 (sim) 13.795.862.371.491.610.020.122.62
ThermoSysPro.Examples.SimpleExamples.TestNTUWaterHeating2 (sim) 25.316.072.371.551.490.040.182.82
ThermoSysPro.Examples.SimpleExamples.TestPipePressureLoss (sim) 0.115.312.371.501.190.010.282.32
ThermoSysPro.Examples.SimpleExamples.TestPressurizer_CC (sim) 0.529.412.422.783.680.030.102.82
ThermoSysPro.Examples.SimpleExamples.TestRefP (sim) 0.167.722.372.792.090.020.102.72
ThermoSysPro.Examples.SimpleExamples.TestSensors (sim) 0.219.022.322.892.850.020.602.67
ThermoSysPro.Examples.SimpleExamples.TestSimpleEvaporatorWaterSteamFlueGases (sim) 0.265.662.372.320.930.010.082.32
ThermoSysPro.Examples.SimpleExamples.TestSimpleStaticCondenser (sim) 0.364.462.371.150.870.010.112.32
ThermoSysPro.Examples.SimpleExamples.TestSingularPressureLoss (sim) 0.115.262.371.511.180.010.232.32
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPump (sim) 0.674.462.371.200.790.020.092.37
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPump1 (sim) 0.065.462.371.481.200.010.412.37
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPump2 (sim) 0.874.722.371.200.870.020.112.53
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPumpWaterSolution (sim) 0.063.012.370.840.050.030.062.02
ThermoSysPro.Examples.SimpleExamples.TestStaticCondenser (sim) 1.125.812.371.581.470.030.122.62
ThermoSysPro.Examples.SimpleExamples.TestStaticDrum1 (sim) 0.035.222.421.221.380.020.132.47
ThermoSysPro.Examples.SimpleExamples.TestStaticDrum2 (sim) 0.425.172.371.231.350.020.112.47
ThermoSysPro.Examples.SimpleExamples.TestStaticExchangerWaterSteamFlueGases (sim) 0.215.862.372.390.920.010.122.42
ThermoSysPro.Examples.SimpleExamples.TestStaticWaterWaterExchanger (sim) 0.164.572.371.160.890.030.122.37
ThermoSysPro.Examples.SimpleExamples.TestStaticWaterWaterExchangerDTorWorEff (sim) 0.524.412.371.170.860.020.102.27
ThermoSysPro.Examples.SimpleExamples.TestSteamDryer1 (sim) 0.315.512.371.491.220.020.312.47
ThermoSysPro.Examples.SimpleExamples.TestSteamDryer2 (sim) 0.375.112.371.211.350.020.122.42
ThermoSysPro.Examples.SimpleExamples.TestSteamEngine (sim) 0.215.462.371.631.010.020.442.37
ThermoSysPro.Examples.SimpleExamples.TestSteamExtractionSplitter (sim) 0.365.412.321.491.220.020.272.42
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine (sim) 1.626.912.371.822.120.030.132.82
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine1 (sim) 0.676.512.321.821.810.020.132.72
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine2 (sim) 0.266.462.371.761.960.020.112.62
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine3 (sim) 0.036.722.321.792.020.030.112.77
ThermoSysPro.Examples.SimpleExamples.TestSwitchValve (sim) 0.318.822.322.882.690.020.502.72
ThermoSysPro.Examples.SimpleExamples.TestTank (sim) 1.579.122.472.873.170.020.132.92
ThermoSysPro.Examples.SimpleExamples.TestThreeWayValve (sim) 0.825.562.371.501.230.200.112.52
ThermoSysPro.Examples.SimpleExamples.TestVolumeATh (sim) 1.228.332.372.792.660.020.142.72
ThermoSysPro.Examples.SimpleExamples.TestVolumes (sim) 3.279.422.372.913.240.030.173.07
ThermoSysPro.Examples.SimpleExamples.TestVolumes1 (sim) 3.279.172.372.913.050.030.153.02
ThermoSysPro.Examples.SimpleExamples.TestVolumes2 (sim) 9.799.232.372.913.210.030.162.92
ThermoSysPro.Properties.WaterSteamSimple.Validation.Bench.Test1_IF97 (sim) 206.079.692.473.012.900.030.323.42
ThermoSysPro.Properties.WaterSteamSimple.Validation.Bench.Test1_polynomial (sim) 0.0310.272.473.302.980.030.543.42
ThermoSysPro.Properties.WaterSteamSimple.Validation.Bench.Test2_IF97 (sim) 1.829.822.423.102.860.020.523.32
ThermoSysPro.Properties.WaterSteamSimple.Validation.Bench.Test2_polynomial (sim) 0.039.722.473.122.800.030.413.37
ThermoSysPro.Properties.WaterSteamSimple.Validation.Bench.Test3_IF97 (sim) 9.3310.272.473.283.350.030.183.42
ThermoSysPro.Properties.WaterSteamSimple.Validation.calculette_T (sim) 0.033.462.470.510.010.000.072.87
ThermoSysPro.Properties.WaterSteamSimple.Validation.calculette_d (sim) 0.033.112.970.620.010.010.052.42
ThermoSysPro.Properties.WaterSteamSimple.Validation.calculette_h 0.000.000.000.000.000.000.000.00
ThermoSysPro.Properties.WaterSteamSimple.Validation.calculette_p 0.000.000.000.000.000.000.000.00