Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr ThermoPower_ThermoPower.PowerPlants.ElectricGeneratorGroup.Tests.Test_Generator_SE.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoPower 3.1.0-master/package.mo", uses=false) Using package ThermoPower with version 3.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoPower 3.1.0-master/package.mo) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Running command: translateModel(ThermoPower.PowerPlants.ElectricGeneratorGroup.Tests.Test_Generator_SE,tolerance=1e-06,outputFormat="empty",numberOfIntervals=100000,variableFilter="",fileNamePrefix="ThermoPower_ThermoPower.PowerPlants.ElectricGeneratorGroup.Tests.Test_Generator_SE") translateModel(ThermoPower.PowerPlants.ElectricGeneratorGroup.Tests.Test_Generator_SE,tolerance=1e-06,outputFormat="empty",numberOfIntervals=100000,variableFilter="",fileNamePrefix="ThermoPower_ThermoPower.PowerPlants.ElectricGeneratorGroup.Tests.Test_Generator_SE") [:1:1-1:32:writable] Error: Class GC_set_max_heap_size not found in scope (looking for a function or record). Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001073/0.001073, allocations: 190.9 kB / 8.133 MB, free: 2.203 MB / 5.871 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.117/1.117, allocations: 205.2 MB / 213.7 MB, free: 13.92 MB / 186.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.0008458/0.0008458, allocations: 99.48 kB / 261.7 MB, free: 13.55 MB / 218.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoPower 3.1.0-master/package.mo): time 0.3016/0.3016, allocations: 48.75 MB / 358.4 MB, free: 53.18 MB / 298.7 MB Notification: Performance of FrontEnd - loaded program: time 5.46e-06/5.481e-06, allocations: 0 / 424.7 MB, free: 8.203 MB / 314.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.09811/0.09812, allocations: 60.25 MB / 485 MB, free: 11.81 MB / 378.7 MB Notification: Performance of FrontEnd - scodeFlatten: time 4.189/4.287, allocations: 2.95 GB / 3.424 GB, free: 110.3 MB / 0.5105 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0001715/4.288, allocations: 81.61 kB / 3.424 GB, free: 110.2 MB / 0.5105 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoPower 3.1.0-master/PowerPlants.mo:17228:11-17228:64:writable] Error: Variable powerConnection.f not found in scope ThermoPower.PowerPlants.ElectricGeneratorGroup.Components.OldElementsSwingEquation.Generator_SE$generator_SE. Error: Error occurred while flattening model ThermoPower.PowerPlants.ElectricGeneratorGroup.Tests.Test_Generator_SE