Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr SiemensPower_OMCtest_SiemensPower.Components.Valves.Tests.valve_test.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.1.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 1.0.0/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/SiemensPower OMCtest/package.mo", uses=false) Using package SiemensPower with version OMCtest (/home/hudson/saved_omc/libraries/.openmodelica/libraries/SiemensPower OMCtest/package.mo) Using package ModelicaServices with version 1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 1.0.0/package.mo) Using package Modelica with version 3.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.1.0+maint.om/package.mo) Running command: translateModel(SiemensPower.Components.Valves.Tests.valve_test,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="SiemensPower_OMCtest_SiemensPower.Components.Valves.Tests.valve_test") translateModel(SiemensPower.Components.Valves.Tests.valve_test,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="SiemensPower_OMCtest_SiemensPower.Components.Valves.Tests.valve_test") [:1:1-1:32:writable] Error: Class GC_set_max_heap_size not found in scope (looking for a function or record). Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.1.0+maint.om/package.mo): time 0.52/0.52, allocations: 110.8 MB / 118 MB, free: 3.379 MB / 98.76 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 1.0.0/package.mo): time 0.001508/0.001508, allocations: 152 kB / 143.7 MB, free: 9.672 MB / 130.8 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/SiemensPower OMCtest/package.mo): time 0.01722/0.01722, allocations: 3.966 MB / 173.2 MB, free: 13.86 MB / 130.8 MB Notification: Performance of FrontEnd - loaded program: time 4.108e-06/4.128e-06, allocations: 0 / 204.6 MB, free: 14.4 MB / 162.8 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.0889/0.08891, allocations: 26.08 MB / 230.7 MB, free: 23.64 MB / 162.8 MB Notification: Performance of FrontEnd - scodeFlatten: time 2.41/2.498, allocations: 1.809 GB / 2.034 GB, free: 58.48 MB / 242.8 MB Notification: Performance of FrontEnd - mkProgramGraph: time 7.889e-05/2.499, allocations: 49.61 kB / 2.034 GB, free: 58.48 MB / 242.8 MB Notification: Performance of FrontEnd: time 1.422/3.921, allocations: 0.5865 GB / 2.621 GB, free: 3.094 MB / 274.8 MB Notification: Performance of Transformations before backend: time 7.411e-05/3.921, allocations: 31.75 kB / 2.621 GB, free: 3.066 MB / 274.8 MB Error: Too few equations, under-determined system. The model has 237 equation(s) and 239 variable(s). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/SiemensPower OMCtest/Boundaries/GasSinkP.mo:24:3-28:24:writable] Warning: Variable gasSinkP.Xi_In[1] does not have any remaining equation to be solved in. The original equations were: [/home/hudson/saved_omc/libraries/.openmodelica/libraries/SiemensPower OMCtest/Boundaries/GasSourceP.mo:31:3-35:24:writable] Warning: Variable gasSourceP.Xi_In[1] does not have any remaining equation to be solved in. The original equations were: