Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr PowerSystems_latest_PowerSystems.Examples.AC3ph.Generation.Islanding.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerSystems 1.0.1-master/package.mo", uses=false) Using package PowerSystems with version 1.0.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerSystems 1.0.1-master/package.mo) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Running command: translateModel(PowerSystems.Examples.AC3ph.Generation.Islanding,tolerance=1e-06,outputFormat="mat",numberOfIntervals=5000,variableFilter="ACpower.p.1.|ACpower.p.2.|ACpower.p.3.|DCpower.p|DCvoltage.v|Time",fileNamePrefix="PowerSystems_latest_PowerSystems.Examples.AC3ph.Generation.Islanding") translateModel(PowerSystems.Examples.AC3ph.Generation.Islanding,tolerance=1e-06,outputFormat="mat",numberOfIntervals=5000,variableFilter="ACpower.p.1.|ACpower.p.2.|ACpower.p.3.|DCpower.p|DCvoltage.v|Time",fileNamePrefix="PowerSystems_latest_PowerSystems.Examples.AC3ph.Generation.Islanding") [:1:1-1:32:writable] Error: Class GC_set_max_heap_size not found in scope (looking for a function or record). Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001456/0.001456, allocations: 183.6 kB / 8.138 MB, free: 2.199 MB / 5.871 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.408/1.408, allocations: 205.2 MB / 213.7 MB, free: 13.86 MB / 186.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.0008536/0.0008536, allocations: 89.62 kB / 261.7 MB, free: 13.55 MB / 218.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerSystems 1.0.1-master/package.mo): time 0.1671/0.1671, allocations: 37.97 MB / 347.7 MB, free: 7.477 MB / 298.7 MB Notification: Performance of FrontEnd - loaded program: time 8.025e-06/8.215e-06, allocations: 0 / 410 MB, free: 46.88 MB / 298.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.1097/0.1097, allocations: 56.31 MB / 466.3 MB, free: 6.484 MB / 314.7 MB Notification: Performance of FrontEnd - scodeFlatten: time 0.3744/0.4841, allocations: 136.8 MB / 0.5889 GB, free: 5.773 MB / 426.7 MB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002994/0.4845, allocations: 95.94 kB / 0.589 GB, free: 5.68 MB / 426.7 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerSystems 1.0.1-master/AC3ph/Machines.mo:2240:3-2240:48:writable] Error: Could not evaluate structural parameter (or constant): n_d which gives dimensions of array: L_rd[n_d]. Array dimensions must be known at compile time. Error: Error occurred while flattening model PowerSystems.Examples.AC3ph.Generation.Islanding