OMSimulator -r ModelicaTest_3.2.2_fmi_ModelicaTest.Fluid.TestPipesAndValves.BranchingPipes3_res.mat --tempDir temp_ModelicaTest_3_2_2_fmi_ModelicaTest_Fluid_TestPipesAndValves_BranchingPipes3_fmu --startTime 0 --stopTime 5 --tolerance 1e-06 ModelicaTest_3_2_2_fmi_ModelicaTest_Fluid_TestPipesAndValves_BranchingPipes3.fmu info: Initializing logging (OMSimulator v0.0.0-204-g82c54af) info: new temp directory has been created: "temp_ModelicaTest_3_2_2_fmi_ModelicaTest_Fluid_TestPipesAndValves_BranchingPipes3_fmu" info: Using "/var/lib/hudson/slave/workspace/OpenModelica_TEST_LIBS/OpenModelicaLibraryTesting/ModelicaTest_3.2.2_fmi_ModelicaTest.Fluid.TestPipesAndValves.BranchingPipes3/temp_ModelicaTest_3_2_2_fmi_ModelicaTest_Fluid_TestPipesAndValves_BranchingPipes3_fmu/temp_wi9UtP" as temp directory for fmu stdout | info | The initialization finished successfully without homotopy method. info: Result file: ModelicaTest_3.2.2_fmi_ModelicaTest.Fluid.TestPipesAndValves.BranchingPipes3_res.mat assert | error | IF97 medium function tsat called with too low pressure | | | | p = -339075 Pa <= 611.657 Pa (triple point pressure) error: ME-FMU instance (logFmi2Call): fmi2GetDerivatives: terminated by an assertion. fatal: fmi2_import_get_derivatives failed info: 0 warnings info: 2 errors info: Logging completed properly info: Initializing logging (OMSimulator v0.0.0-204-g82c54af) fatal: Time measurement is corrupted.