OMSimulator -r ModelicaTest_3.2.2_fmi_ModelicaTest.Fluid.TestComponents.Vessels.TestSimpleTank_res.mat --tempDir temp_ModelicaTest_3_2_2_fmi_ModelicaTest_Fluid_TestComponents_Vessels_TestSimpleTank_fmu --startTime 0 --stopTime 100 --tolerance 1e-06 ModelicaTest_3_2_2_fmi_ModelicaTest_Fluid_TestComponents_Vessels_TestSimpleTank.fmu info: Initializing logging (OMSimulator v0.0.0-204-g82c54af) info: new temp directory has been created: "temp_ModelicaTest_3_2_2_fmi_ModelicaTest_Fluid_TestComponents_Vessels_TestSimpleTank_fmu" info: Using "/var/lib/hudson/slave/workspace/OpenModelica_TEST_LIBS/OpenModelicaLibraryTesting/ModelicaTest_3.2.2_fmi_ModelicaTest.Fluid.TestComponents.Vessels.TestSimpleTank/temp_ModelicaTest_3_2_2_fmi_ModelicaTest_Fluid_TestComponents_Vessels_TestSimpleTank_fmu/temp_druSBv" as temp directory for fmu stdout | info | The initialization finished successfully without homotopy method. info: Result file: ModelicaTest_3.2.2_fmi_ModelicaTest.Fluid.TestComponents.Vessels.TestSimpleTank_res.mat assert | warning | The following assertion has been violated at time 0.000000 | | | | tank.medium.T >= 272.15 and tank.medium.T <= 403.15 assert | error | | | | | Temperature T (= -13736.7 K) is not | | | | in the allowed range (272.15 K <= T <= 403.15 K) | | | | required from medium model "SimpleLiquidWater". error: ME-FMU instance (logFmi2Call): fmi2CompletedIntegratorStep: terminated by an assertion. fatal: fmi2_import_completed_integrator_step failed info: 0 warnings info: 2 errors info: Logging completed properly info: Initializing logging (OMSimulator v0.0.0-204-g82c54af) fatal: Time measurement is corrupted.