OMSimulator -r ModelicaTest_3.2.2_fmi_ModelicaTest.Fluid.TestComponents.Machines.TestSweptVolume_res.mat --tempDir temp_ModelicaTest_3_2_2_fmi_ModelicaTest_Fluid_TestComponents_Machines_TestSweptVolume_fmu --startTime 0 --stopTime 5 --tolerance 1e-06 ModelicaTest_3_2_2_fmi_ModelicaTest_Fluid_TestComponents_Machines_TestSweptVolume.fmu info: Initializing logging (OMSimulator v0.0.0-204-g82c54af) info: new temp directory has been created: "temp_ModelicaTest_3_2_2_fmi_ModelicaTest_Fluid_TestComponents_Machines_TestSweptVolume_fmu" info: Using "/var/lib/hudson/slave/workspace/OpenModelica_TEST_LIBS/OpenModelicaLibraryTesting/ModelicaTest_3.2.2_fmi_ModelicaTest.Fluid.TestComponents.Machines.TestSweptVolume/temp_ModelicaTest_3_2_2_fmi_ModelicaTest_Fluid_TestComponents_Machines_TestSweptVolume_fmu/temp_knovKH" as temp directory for fmu stdout | info | The initialization finished successfully without homotopy method. info: Result file: ModelicaTest_3.2.2_fmi_ModelicaTest.Fluid.TestComponents.Machines.TestSweptVolume_res.mat assert | warning | The following assertion has been violated at time 4.410000 | | | | sweptVolume.flange.s >= 0.0 assert | error | Piston stroke (given by flange.s) must not be smaller than zero! error: ME-FMU instance (logFmi2Call): fmi2CompletedIntegratorStep: terminated by an assertion. fatal: fmi2_import_completed_integrator_step failed info: 0 warnings info: 2 errors info: Logging completed properly info: Initializing logging (OMSimulator v0.0.0-204-g82c54af) fatal: Time measurement is corrupted.