startTime=0 stopTime=1.01 tolerance=1e-06 numberOfIntervals=2500 stepSize=0.000404 Regular simulation: ./ModelicaTest_3.2.2_ModelicaTest.Fluid.TestComponents.Sensors.TestSpecificEnthalpy -abortSlowSimulation -alarm=480 -lv LOG_STATS stdout | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.00183215s reading init.xml | | | | | | 0.000163207s reading info.xml | | | | | | 5.343e-05s pre-initialization | | | | | | 0.000221726s [ 0.2%] initialization | | | | | | 1.57e-05s [ 0.0%] steps | | | | | | 0s [ 0.0%] creating output-file | | | | | | 0.00107113s [ 1.2%] event-handling | | | | | | 0.00792729s [ 8.7%] overhead | | | | | | 0.0814389s [ 89.8%] simulation | | | | | | 0.0907282s [100.0%] total | | | | | events | | | | | | 4 state events | | | | | | 0 time events | | | | | solver: euler | | | | | | 14913 steps taken | | | | | | 14913 calls of functionODE | | | | | | 0 evaluations of jacobian | | | | | | 0 error test failures | | | | | | 0 convergence test failures | | | | | | 0s time of jacobian evaluation stdout | info | The simulation finished successfully.