Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_maint.7.0.x_Buildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.IntegratedPrimarySecondary.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.3-maint.7.0.x/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 7.0.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.3-maint.7.0.x/package.mo) Running command: translateModel(Buildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.IntegratedPrimarySecondary,tolerance=1e-06,outputFormat="mat",numberOfIntervals=5000,variableFilter="time|onChi.y|onWSE.y|tri.y|sou1.T_in|sou2.T_in|intWSEPriSec1.wse.heaExc.con.addPID.y|intWSEPriSec2.wse.heaExc.con.addPID.y|TSup1.T|TSup2.T|intWSEPriSec1.TCHWSupWSE|intWSEPriSec2.TCHWSupWSE|intWSEPriSec1.chiPar.port_a1.m_flow|intWSEPriSec1.chiPar.port_a2.m_flow|intWSEPriSec2.chiPar.port_a1.m_flow|intWSEPriSec2.chiPar.port_a2.m_flow|intWSEPriSec1.chiPar.P.1.|intWSEPriSec2.chiPar.P.1.",fileNamePrefix="Buildings_maint.7.0.x_Buildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.IntegratedPrimarySecondary") translateModel(Buildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.IntegratedPrimarySecondary,tolerance=1e-06,outputFormat="mat",numberOfIntervals=5000,variableFilter="time|onChi.y|onWSE.y|tri.y|sou1.T_in|sou2.T_in|intWSEPriSec1.wse.heaExc.con.addPID.y|intWSEPriSec2.wse.heaExc.con.addPID.y|TSup1.T|TSup2.T|intWSEPriSec1.TCHWSupWSE|intWSEPriSec2.TCHWSupWSE|intWSEPriSec1.chiPar.port_a1.m_flow|intWSEPriSec1.chiPar.port_a2.m_flow|intWSEPriSec2.chiPar.port_a1.m_flow|intWSEPriSec2.chiPar.port_a2.m_flow|intWSEPriSec1.chiPar.P.1.|intWSEPriSec2.chiPar.P.1.",fileNamePrefix="Buildings_maint.7.0.x_Buildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.IntegratedPrimarySecondary") [:1:1-1:32:writable] Error: Class GC_set_max_heap_size not found in scope (looking for a function or record). Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.3-maint.7.0.x/package.mo): time 1.38/1.38, allocations: 249.4 MB / 256.7 MB, free: 7.004 MB / 202.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001711/0.001711, allocations: 189.2 kB / 316 MB, free: 3.508 MB / 250.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.564/1.564, allocations: 205.2 MB / 0.5667 GB, free: 15.66 MB / 426.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.0008985/0.0008984, allocations: 93.02 kB / 0.671 GB, free: 4.785 MB / 0.5105 GB Notification: Performance of FrontEnd - loaded program: time 1.053e-05/1.056e-05, allocations: 4 kB / 0.7807 GB, free: 103 MB / 0.5417 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.2458/0.2459, allocations: 106.3 MB / 0.8846 GB, free: 12.61 MB / 0.5573 GB Notification: Performance of FrontEnd - scodeFlatten: time 1.665/1.911, allocations: 0.5017 GB / 1.386 GB, free: 232.2 MB / 0.8698 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0003529/1.912, allocations: 107.9 kB / 1.386 GB, free: 232.1 MB / 0.8698 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.3-maint.7.0.x/Applications/DataCenters/ChillerCooled/Equipment/IntegratedPrimarySecondary.mo:121:11-121:21:writable] Error: Type mismatch in binding pressure = Buildings.Fluid.Movers.BaseClasses.Characteristics.flowParameters$intWSEPriSec1$perPum$pressure({0, 0}, {0, 0}), expected subtype of record Buildings.Fluid.Movers.BaseClasses.Characteristics.flowParameters Real(min = 0.0, quantity = "VolumeFlowRate", unit = "m3/s")[2] V_flow; Real(min = 0.0, displayUnit = "Pa", quantity = "Pressure", unit = "Pa")[2] dp; end Buildings.Fluid.Movers.BaseClasses.Characteristics.flowParameters;, got type record Buildings.Fluid.Movers.BaseClasses.Characteristics.flowParameters$intWSEPriSec1$perPum$pressure Integer[2] V_flow; Integer[2] dp; end Buildings.Fluid.Movers.BaseClasses.Characteristics.flowParameters$intWSEPriSec1$perPum$pressure;. Error: Error occurred while flattening model Buildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.IntegratedPrimarySecondary