startTime=0 stopTime=3600 tolerance=1e-06 numberOfIntervals=2500 stepSize=1.44 Regular simulation: ./Buildings_latest_Buildings.Fluid.MixingVolumes.Validation.CoupledVolumesSpecializedAirPerfectGas -abortSlowSimulation -alarm=480 -emit_protected -lv LOG_STATS stdout | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.00346418s reading init.xml | | | | | | 0.000595277s reading info.xml | | | | | | 0.000248156s pre-initialization | | | | | | 0.000158166s [ 0.6%] initialization | | | | | | 2.645e-06s [ 0.0%] steps | | | | | | 0.00095716s [ 3.9%] creating output-file | | | | | | 8.3706e-05s [ 0.3%] event-handling | | | | | | 0.010154s [ 41.0%] overhead | | | | | | 0.0131694s [ 53.2%] simulation | | | | | | 0.0247733s [100.0%] total | | | | | events | | | | | | 0 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 23 steps taken | | | | | | 23 calls of functionODE | | | | | | 22 evaluations of jacobian | | | | | | 0 error test failures | | | | | | 0 convergence test failures | | | | | | 0.000239191s time of jacobian evaluation stdout | info | The simulation finished successfully.