Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_latest_Buildings.Experimental.DHC.Plants.Cooling.Examples.ElectricChillerParallel.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Using package Modelica with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package Buildings with version 10.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/package.mo) Running command: translateModel(Buildings.Experimental.DHC.Plants.Cooling.Examples.ElectricChillerParallel,tolerance=1e-06,outputFormat="mat",numberOfIntervals=5000,variableFilter="time|pla.PCoo|loaVar.y|pla.chiStaCon.plr.y|pla.chiStaCon.y.1.|pla.chiStaCon.y.2.|pla.senMasFlo.m_flow|pla.splCHWSup.port_1.m_flow|pla.splCHWSup.port_2.m_flow|pla.splCHWSup.port_3.m_flow|pla.cooTowWitByp.TWetBul|pla.cooTowWitByp.TLvg|pla.senTCHWSup.T|pla.senTCHWRet.T",fileNamePrefix="Buildings_latest_Buildings.Experimental.DHC.Plants.Cooling.Examples.ElectricChillerParallel") translateModel(Buildings.Experimental.DHC.Plants.Cooling.Examples.ElectricChillerParallel,tolerance=1e-06,outputFormat="mat",numberOfIntervals=5000,variableFilter="time|pla.PCoo|loaVar.y|pla.chiStaCon.plr.y|pla.chiStaCon.y.1.|pla.chiStaCon.y.2.|pla.senMasFlo.m_flow|pla.splCHWSup.port_1.m_flow|pla.splCHWSup.port_2.m_flow|pla.splCHWSup.port_3.m_flow|pla.cooTowWitByp.TWetBul|pla.cooTowWitByp.TLvg|pla.senTCHWSup.T|pla.senTCHWRet.T",fileNamePrefix="Buildings_latest_Buildings.Experimental.DHC.Plants.Cooling.Examples.ElectricChillerParallel") [:1:1-1:32:writable] Error: Class GC_set_max_heap_size not found in scope (looking for a function or record). Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/package.mo): time 1.916/1.916, allocations: 390.4 MB / 397.7 MB, free: 10.68 MB / 330.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.00126/0.00126, allocations: 181.5 kB / 490.8 MB, free: 11.24 MB / 394.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo): time 1.367/1.367, allocations: 221.4 MB / 0.7863 GB, free: 13.59 MB / 0.5886 GB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.000956/0.0009561, allocations: 99.77 kB / 0.9264 GB, free: 4.582 MB / 0.6667 GB Notification: Performance of FrontEnd - loaded program: time 7.144e-06/7.464e-06, allocations: 0 / 1.072 GB, free: 15.61 MB / 0.823 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.838/0.838, allocations: 143 MB / 1.212 GB, free: 156 MB / 0.8855 GB Notification: Performance of FrontEnd - scodeFlatten: time 4.376/5.214, allocations: 2.34 GB / 3.552 GB, free: 228.8 MB / 1.167 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002737/5.214, allocations: 104.7 kB / 3.552 GB, free: 228.7 MB / 1.167 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/Fluid/Movers/Data/Generic.mo:7:3-11:47:writable] Error: Array equation has unknown size in perCHWPum.pressure.V_flow={0.00366, 0.01098, 0.01464, 0.0183}. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/Fluid/Movers/BaseClasses/Euler/getPeak.mo:9:3-10:49:writable] Warning: Component peak in env: Buildings.Fluid.Movers.BaseClasses.Euler.getPeak has the same name as its type Buildings.Fluid.Movers.BaseClasses.Euler.peak. This is forbidden by Modelica specification and may lead to lookup errors. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/Fluid/Movers/Data/Generic.mo:90:3-92:29:writable] Error: Class Buildings.Fluid.Movers.BaseClasses.Euler.getPeak not found in scope Buildings.Fluid.Movers.Data.Generic$perCHWPum (looking for a function or record). Error: Error occurred while flattening model Buildings.Experimental.DHC.Plants.Cooling.Examples.ElectricChillerParallel