Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_latest_Buildings.Experimental.DHC.EnergyTransferStations.Cooling.Examples.Direct.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Using package Modelica with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package Buildings with version 10.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/package.mo) Running command: translateModel(Buildings.Experimental.DHC.EnergyTransferStations.Cooling.Examples.Direct,tolerance=1e-06,outputFormat="mat",numberOfIntervals=5000,variableFilter="time|cooETS.senTDisSup.T|cooETS.senTBuiSup.T|cooETS.senTBuiRet.T|cooETS.senTDisRet.T|cooETS.port_aSerCoo.m_flow|cooETS.ports_aChiWat.1..m_flow|cooETS.cheVal.m_flow|cooETS.conVal.y|cooETS.Q_flow|cooETS.Q",fileNamePrefix="Buildings_latest_Buildings.Experimental.DHC.EnergyTransferStations.Cooling.Examples.Direct") translateModel(Buildings.Experimental.DHC.EnergyTransferStations.Cooling.Examples.Direct,tolerance=1e-06,outputFormat="mat",numberOfIntervals=5000,variableFilter="time|cooETS.senTDisSup.T|cooETS.senTBuiSup.T|cooETS.senTBuiRet.T|cooETS.senTDisRet.T|cooETS.port_aSerCoo.m_flow|cooETS.ports_aChiWat.1..m_flow|cooETS.cheVal.m_flow|cooETS.conVal.y|cooETS.Q_flow|cooETS.Q",fileNamePrefix="Buildings_latest_Buildings.Experimental.DHC.EnergyTransferStations.Cooling.Examples.Direct") [:1:1-1:32:writable] Error: Class GC_set_max_heap_size not found in scope (looking for a function or record). Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/package.mo): time 1.993/1.993, allocations: 390.4 MB / 397.7 MB, free: 11.25 MB / 314.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.0009986/0.0009986, allocations: 177.3 kB / 490.8 MB, free: 1.926 MB / 394.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo): time 1.229/1.229, allocations: 221.3 MB / 0.7863 GB, free: 13.67 MB / 0.5573 GB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.0008188/0.0008186, allocations: 88.67 kB / 0.9264 GB, free: 14.2 MB / 0.698 GB Notification: Performance of FrontEnd - loaded program: time 5.099e-06/5.119e-06, allocations: 0 / 1.072 GB, free: 182.6 MB / 0.7605 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.2102/0.2102, allocations: 143 MB / 1.212 GB, free: 40.1 MB / 0.7605 GB Notification: Performance of FrontEnd - scodeFlatten: time 0.8619/1.072, allocations: 498.4 MB / 1.698 GB, free: 14.46 MB / 1.12 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002604/1.072, allocations: 101.1 kB / 1.698 GB, free: 14.4 MB / 1.12 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/Fluid/Movers/BaseClasses/Euler/getPeak.mo:9:3-10:49:writable] Warning: Component peak in env: Buildings.Fluid.Movers.BaseClasses.Euler.getPeak has the same name as its type Buildings.Fluid.Movers.BaseClasses.Euler.peak. This is forbidden by Modelica specification and may lead to lookup errors. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/Fluid/Movers/Data/Generic.mo:90:3-92:29:writable] Error: Class Buildings.Fluid.Movers.BaseClasses.Euler.getPeak not found in scope Buildings.Fluid.Movers.Data.Generic (looking for a function or record). Error: Error occurred while flattening model Buildings.Experimental.DHC.EnergyTransferStations.Cooling.Examples.Direct