Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_latest_Buildings.Experimental.DHC.EnergyTransferStations.Combined.Subsystems.Validation.HeatExchanger.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Using package Modelica with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package Buildings with version 10.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/package.mo) Running command: translateModel(Buildings.Experimental.DHC.EnergyTransferStations.Combined.Subsystems.Validation.HeatExchanger,tolerance=1e-06,outputFormat="mat",numberOfIntervals=5000,variableFilter="time|senT1InlPum.T|senT1OutPum.T|senT2InlPum.T|senT2OutPum.T|hexPum.m1_flow|hexPum.m2_flow|hexPum.m1_flow_nominal|hexPum.m2_flow_nominal|hexPum.con.y1|hexPum.con.yVal2|hexPum.con.yPum2|senT1InlVal.T|senT1OutVal.T|senT2InlVal.T|senT2OutVal.T|hexVal.m1_flow|hexVal.m2_flow|hexVal.m1_flow_nominal|hexVal.m2_flow_nominal|hexVal.con.y1|hexVal.con.yVal2|hexVal.con.yPum2",fileNamePrefix="Buildings_latest_Buildings.Experimental.DHC.EnergyTransferStations.Combined.Subsystems.Validation.HeatExchanger") translateModel(Buildings.Experimental.DHC.EnergyTransferStations.Combined.Subsystems.Validation.HeatExchanger,tolerance=1e-06,outputFormat="mat",numberOfIntervals=5000,variableFilter="time|senT1InlPum.T|senT1OutPum.T|senT2InlPum.T|senT2OutPum.T|hexPum.m1_flow|hexPum.m2_flow|hexPum.m1_flow_nominal|hexPum.m2_flow_nominal|hexPum.con.y1|hexPum.con.yVal2|hexPum.con.yPum2|senT1InlVal.T|senT1OutVal.T|senT2InlVal.T|senT2OutVal.T|hexVal.m1_flow|hexVal.m2_flow|hexVal.m1_flow_nominal|hexVal.m2_flow_nominal|hexVal.con.y1|hexVal.con.yVal2|hexVal.con.yPum2",fileNamePrefix="Buildings_latest_Buildings.Experimental.DHC.EnergyTransferStations.Combined.Subsystems.Validation.HeatExchanger") [:1:1-1:32:writable] Error: Class GC_set_max_heap_size not found in scope (looking for a function or record). Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/package.mo): time 1.792/1.792, allocations: 390.4 MB / 397.7 MB, free: 11.23 MB / 314.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.0009005/0.0009005, allocations: 179.4 kB / 490.8 MB, free: 1.906 MB / 394.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo): time 1.117/1.117, allocations: 221.4 MB / 0.7863 GB, free: 13.62 MB / 0.5573 GB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.0008043/0.0008043, allocations: 88.69 kB / 0.9264 GB, free: 14.16 MB / 0.698 GB Notification: Performance of FrontEnd - loaded program: time 6.432e-06/6.472e-06, allocations: 4 kB / 1.072 GB, free: 182.5 MB / 0.7605 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.1837/0.1838, allocations: 143 MB / 1.212 GB, free: 40.06 MB / 0.7605 GB Notification: Performance of FrontEnd - scodeFlatten: time 0.765/0.9488, allocations: 495.5 MB / 1.695 GB, free: 0.7461 MB / 1.104 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002642/0.9491, allocations: 110.7 kB / 1.696 GB, free: 0.6836 MB / 1.104 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/Fluid/Movers/BaseClasses/Euler/getPeak.mo:9:3-10:49:writable] Warning: Component peak in env: Buildings.Fluid.Movers.BaseClasses.Euler.getPeak has the same name as its type Buildings.Fluid.Movers.BaseClasses.Euler.peak. This is forbidden by Modelica specification and may lead to lookup errors. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/Fluid/Movers/Data/Generic.mo:90:3-92:29:writable] Error: Class Buildings.Fluid.Movers.BaseClasses.Euler.getPeak not found in scope Buildings.Fluid.Movers.Data.Generic$hexPum$perPum1 (looking for a function or record). Error: Error occurred while flattening model Buildings.Experimental.DHC.EnergyTransferStations.Combined.Subsystems.Validation.HeatExchanger