Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_latest_Buildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.CoolingCoilHumidifyingHeating_OpenLoop.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Using package Modelica with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package Buildings with version 10.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/package.mo) Running command: translateModel(Buildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.CoolingCoilHumidifyingHeating_OpenLoop,tolerance=1e-06,outputFormat="mat",numberOfIntervals=5000,variableFilter="time|ahu.port_a1.m_flow|ahu.port_a2.m_flow|ahu.cooCoi.Q1_flow|ahu.cooCoi.Q2_flow|ahu.cooCoi.QSen2_flow|ahu.cooCoi.QLat2_flow|temSou_2.y|temSenWat1.T|temSenWat2.T|temSenAir2.T",fileNamePrefix="Buildings_latest_Buildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.CoolingCoilHumidifyingHeating_OpenLoop") translateModel(Buildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.CoolingCoilHumidifyingHeating_OpenLoop,tolerance=1e-06,outputFormat="mat",numberOfIntervals=5000,variableFilter="time|ahu.port_a1.m_flow|ahu.port_a2.m_flow|ahu.cooCoi.Q1_flow|ahu.cooCoi.Q2_flow|ahu.cooCoi.QSen2_flow|ahu.cooCoi.QLat2_flow|temSou_2.y|temSenWat1.T|temSenWat2.T|temSenAir2.T",fileNamePrefix="Buildings_latest_Buildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.CoolingCoilHumidifyingHeating_OpenLoop") [:1:1-1:32:writable] Error: Class GC_set_max_heap_size not found in scope (looking for a function or record). Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/package.mo): time 1.727/1.727, allocations: 390.4 MB / 397.7 MB, free: 11.29 MB / 314.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.0008793/0.0008793, allocations: 182.7 kB / 490.8 MB, free: 1.969 MB / 394.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo): time 1.07/1.07, allocations: 221.4 MB / 0.7863 GB, free: 13.76 MB / 0.5573 GB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.0008342/0.0008342, allocations: 88.56 kB / 0.9264 GB, free: 14.29 MB / 0.698 GB Notification: Performance of FrontEnd - loaded program: time 5.06e-06/5.08e-06, allocations: 0 / 1.072 GB, free: 182.6 MB / 0.7605 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.1693/0.1694, allocations: 143 MB / 1.212 GB, free: 40.16 MB / 0.7605 GB Notification: Performance of FrontEnd - scodeFlatten: time 3.363/3.532, allocations: 2.365 GB / 3.576 GB, free: 401.1 MB / 1.151 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.00025/3.533, allocations: 102.6 kB / 3.577 GB, free: 401.1 MB / 1.151 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/Fluid/Movers/BaseClasses/Euler/getPeak.mo:9:3-10:49:writable] Warning: Component peak in env: Buildings.Fluid.Movers.BaseClasses.Euler.getPeak has the same name as its type Buildings.Fluid.Movers.BaseClasses.Euler.peak. This is forbidden by Modelica specification and may lead to lookup errors. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/Fluid/Movers/Data/Generic.mo:90:3-92:29:writable] Error: Class Buildings.Fluid.Movers.BaseClasses.Euler.getPeak not found in scope Buildings.Fluid.Movers.Data.Generic$ahu$perFan (looking for a function or record). Error: Error occurred while flattening model Buildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.CoolingCoilHumidifyingHeating_OpenLoop