Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_9_Buildings.Obsolete.DistrictHeatingCooling.Plants.Validation.Plant_Carnot_T_ClosedLoop.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.1-maint.9.1.x/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Using package Modelica with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package Buildings with version 9.1.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.1-maint.9.1.x/package.mo) Running command: translateModel(Buildings.Obsolete.DistrictHeatingCooling.Plants.Validation.Plant_Carnot_T_ClosedLoop,tolerance=1e-06,outputFormat="mat",numberOfIntervals=5000,variableFilter="time|vol.T|pum.m_flow|pla.QHea_flow|pla.QCoo_flow|pla.sta_a.T|pla.sta_b.T|pla.PComHea|pla.PComCoo",fileNamePrefix="Buildings_9_Buildings.Obsolete.DistrictHeatingCooling.Plants.Validation.Plant_Carnot_T_ClosedLoop") translateModel(Buildings.Obsolete.DistrictHeatingCooling.Plants.Validation.Plant_Carnot_T_ClosedLoop,tolerance=1e-06,outputFormat="mat",numberOfIntervals=5000,variableFilter="time|vol.T|pum.m_flow|pla.QHea_flow|pla.QCoo_flow|pla.sta_a.T|pla.sta_b.T|pla.PComHea|pla.PComCoo",fileNamePrefix="Buildings_9_Buildings.Obsolete.DistrictHeatingCooling.Plants.Validation.Plant_Carnot_T_ClosedLoop") [:1:1-1:32:writable] Error: Class GC_set_max_heap_size not found in scope (looking for a function or record). Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.1-maint.9.1.x/package.mo): time 1.945/1.945, allocations: 387.2 MB / 394.5 MB, free: 13.67 MB / 314.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.001072/0.001072, allocations: 177.3 kB / 487 MB, free: 5.398 MB / 394.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo): time 1.419/1.419, allocations: 221.3 MB / 0.7819 GB, free: 1.391 MB / 0.5417 GB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.0009653/0.0009654, allocations: 100.5 kB / 0.9213 GB, free: 2.641 MB / 0.6823 GB Notification: Performance of FrontEnd - loaded program: time 6.011e-06/6.021e-06, allocations: 0 / 1.066 GB, free: 168.3 MB / 0.7448 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.2833/0.2833, allocations: 142.3 MB / 1.205 GB, free: 26.25 MB / 0.7448 GB Notification: Performance of FrontEnd - scodeFlatten: time 4.066/4.349, allocations: 2.233 GB / 3.438 GB, free: 44.65 MB / 1.151 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002383/4.349, allocations: 93.44 kB / 3.438 GB, free: 44.61 MB / 1.151 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.1-maint.9.1.x/Obsolete/DistrictHeatingCooling/Plants/HeatingCoolingCarnot_T.mo:77:3-91:69:writable] Error: Variable pla.coo: Cyclically dependent constants or parameters found in scope Buildings.Fluid.Chillers.Carnot_TEva$pla$coo: {COP_nominal,etaCarnot_nominal} (ignore with -d=ignoreCycles). Error: Error occurred while flattening model Buildings.Obsolete.DistrictHeatingCooling.Plants.Validation.Plant_Carnot_T_ClosedLoop