Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_9_Buildings.Electrical.AC.ThreePhasesBalanced.Sources.Examples.PVPanels.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.1-maint.9.1.x/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Using package Modelica with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package Buildings with version 9.1.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.1-maint.9.1.x/package.mo) Running command: translateModel(Buildings.Electrical.AC.ThreePhasesBalanced.Sources.Examples.PVPanels,tolerance=1e-06,outputFormat="mat",numberOfIntervals=5000,variableFilter="time|grid.P.real|grid.P.apparent|pvSimple.load.S.1.|pvSimple.load.S.2.|RL.S.1.|RL.S.2.|pvOriented.panel.load.S.1.|pvOriented.panel.load.S.2.",fileNamePrefix="Buildings_9_Buildings.Electrical.AC.ThreePhasesBalanced.Sources.Examples.PVPanels") translateModel(Buildings.Electrical.AC.ThreePhasesBalanced.Sources.Examples.PVPanels,tolerance=1e-06,outputFormat="mat",numberOfIntervals=5000,variableFilter="time|grid.P.real|grid.P.apparent|pvSimple.load.S.1.|pvSimple.load.S.2.|RL.S.1.|RL.S.2.|pvOriented.panel.load.S.1.|pvOriented.panel.load.S.2.",fileNamePrefix="Buildings_9_Buildings.Electrical.AC.ThreePhasesBalanced.Sources.Examples.PVPanels") [:1:1-1:32:writable] Error: Class GC_set_max_heap_size not found in scope (looking for a function or record). Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.1-maint.9.1.x/package.mo): time 1.782/1.782, allocations: 387.2 MB / 394.5 MB, free: 13.68 MB / 314.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.001003/0.001003, allocations: 185.2 kB / 487 MB, free: 5.344 MB / 394.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo): time 1.138/1.138, allocations: 221.3 MB / 0.7819 GB, free: 1.387 MB / 0.5417 GB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.0008542/0.0008543, allocations: 88.08 kB / 0.9213 GB, free: 2.641 MB / 0.6823 GB Notification: Performance of FrontEnd - loaded program: time 5.871e-06/5.901e-06, allocations: 0 / 1.066 GB, free: 168.3 MB / 0.7448 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.1774/0.1775, allocations: 142.3 MB / 1.205 GB, free: 26.23 MB / 0.7448 GB Notification: Performance of FrontEnd - scodeFlatten: time 2.599/2.776, allocations: 1.764 GB / 2.969 GB, free: 67.75 MB / 1.151 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002387/2.776, allocations: 100.4 kB / 2.969 GB, free: 67.69 MB / 1.151 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.1-maint.9.1.x/Electrical/Interfaces/Terminal.mo:7:1-7:54:writable] Error: Could not evaluate structural parameter (or constant): PhaseSystem.n which gives dimensions of array: v[PhaseSystem.n]. Array dimensions must be known at compile time. Error: Error occurred while flattening model Buildings.Electrical.AC.ThreePhasesBalanced.Sources.Examples.PVPanels