Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_9_Buildings.Air.Systems.SingleZone.VAV.Examples.Guideline36.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.1-maint.9.1.x/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Using package Modelica with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package Buildings with version 9.1.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.1-maint.9.1.x/package.mo) Running command: translateModel(Buildings.Air.Systems.SingleZone.VAV.Examples.Guideline36,tolerance=1e-06,outputFormat="mat",numberOfIntervals=480,variableFilter="time|con.TZonCooSet|con.TZonHeaSet|con.TZon|con.yFan|con.yHeaCoi|con.yCooCoi",fileNamePrefix="Buildings_9_Buildings.Air.Systems.SingleZone.VAV.Examples.Guideline36") translateModel(Buildings.Air.Systems.SingleZone.VAV.Examples.Guideline36,tolerance=1e-06,outputFormat="mat",numberOfIntervals=480,variableFilter="time|con.TZonCooSet|con.TZonHeaSet|con.TZon|con.yFan|con.yHeaCoi|con.yCooCoi",fileNamePrefix="Buildings_9_Buildings.Air.Systems.SingleZone.VAV.Examples.Guideline36") [:1:1-1:32:writable] Error: Class GC_set_max_heap_size not found in scope (looking for a function or record). Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.1-maint.9.1.x/package.mo): time 1.842/1.842, allocations: 387.2 MB / 394.5 MB, free: 13.66 MB / 314.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.001044/0.001044, allocations: 180.5 kB / 487 MB, free: 5.387 MB / 394.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo): time 1.227/1.227, allocations: 221.3 MB / 0.7819 GB, free: 1.402 MB / 0.5417 GB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.0009384/0.0009384, allocations: 85.94 kB / 0.9213 GB, free: 2.66 MB / 0.6823 GB Notification: Performance of FrontEnd - loaded program: time 6.462e-06/6.482e-06, allocations: 0 / 1.066 GB, free: 168.3 MB / 0.7448 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.2329/0.233, allocations: 142.3 MB / 1.205 GB, free: 26.25 MB / 0.7448 GB Notification: Performance of FrontEnd - scodeFlatten: time 3.911/4.144, allocations: 2.427 GB / 3.632 GB, free: 322.8 MB / 1.151 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002255/4.144, allocations: 103.8 kB / 3.632 GB, free: 322.7 MB / 1.151 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.1-maint.9.1.x/HeatTransfer/Data/OpaqueConstructions.mo:9:4-11:111:writable] Error: Could not evaluate structural parameter (or constant): nLay which gives dimensions of array: material[nLay]. Array dimensions must be known at compile time. Error: Error occurred while flattening model Buildings.Air.Systems.SingleZone.VAV.Examples.Guideline36