Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_8_Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.OnlyExteriorWallWithWindowInteriorShade.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 8.1.4 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/package.mo) Running command: translateModel(Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.OnlyExteriorWallWithWindowInteriorShade,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_8_Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.OnlyExteriorWallWithWindowInteriorShade") translateModel(Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.OnlyExteriorWallWithWindowInteriorShade,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_8_Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.OnlyExteriorWallWithWindowInteriorShade") [:1:1-1:32:writable] Error: Class GC_set_max_heap_size not found in scope (looking for a function or record). Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/package.mo): time 1.504/1.504, allocations: 289.8 MB / 297.1 MB, free: 6.598 MB / 234.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001316/0.001316, allocations: 177.3 kB / 366.3 MB, free: 1.938 MB / 298.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.431/1.431, allocations: 205.1 MB / 0.6256 GB, free: 5.793 MB / 474.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.0008932/0.0008935, allocations: 81.86 kB / 0.7395 GB, free: 39.63 MB / 0.5105 GB Notification: Performance of FrontEnd - loaded program: time 7.845e-06/8.186e-06, allocations: 0 / 0.859 GB, free: 13.33 MB / 0.6042 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.6636/0.6637, allocations: 116.3 MB / 0.9726 GB, free: 68.62 MB / 0.6511 GB Notification: Performance of FrontEnd - scodeFlatten: time 4.653/5.316, allocations: 2.218 GB / 3.191 GB, free: 227.4 MB / 0.948 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002373/5.317, allocations: 96.41 kB / 3.191 GB, free: 227.3 MB / 0.948 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/HeatTransfer/Data/OpaqueConstructions.mo:9:4-11:111:writable] Error: Could not evaluate structural parameter (or constant): nLay which gives dimensions of array: material[nLay]. Array dimensions must be known at compile time. Error: Error occurred while flattening model Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.OnlyExteriorWallWithWindowInteriorShade