Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_8_Buildings.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.LoadAggregation.Validation.TemporalSuperposition.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 8.1.4 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/package.mo) Running command: translateModel(Buildings.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.LoadAggregation.Validation.TemporalSuperposition,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_8_Buildings.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.LoadAggregation.Validation.TemporalSuperposition") translateModel(Buildings.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.LoadAggregation.Validation.TemporalSuperposition,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_8_Buildings.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.LoadAggregation.Validation.TemporalSuperposition") [:1:1-1:32:writable] Error: Class GC_set_max_heap_size not found in scope (looking for a function or record). Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/package.mo): time 1.569/1.569, allocations: 289.8 MB / 297.1 MB, free: 6.691 MB / 234.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001072/0.001072, allocations: 181.3 kB / 366.3 MB, free: 2.008 MB / 298.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.557/1.557, allocations: 205.1 MB / 0.6256 GB, free: 5.844 MB / 474.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.0009079/0.0009078, allocations: 80.88 kB / 0.7395 GB, free: 39.71 MB / 0.5105 GB Notification: Performance of FrontEnd - loaded program: time 9.097e-06/9.127e-06, allocations: 4 kB / 0.8591 GB, free: 13.36 MB / 0.6042 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.6307/0.6307, allocations: 116.3 MB / 0.9726 GB, free: 68.49 MB / 0.6511 GB Notification: Performance of FrontEnd - scodeFlatten: time 0.1791/0.8099, allocations: 138.3 MB / 1.108 GB, free: 10.19 MB / 0.7136 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002861/0.8102, allocations: 99.91 kB / 1.108 GB, free: 10.09 MB / 0.7136 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/Fluid/Geothermal/Borefields/BaseClasses/HeatTransfer/LoadAggregation/Validation/TemporalSuperposition.mo:5:3-9:41:writable] Error: No matching function found for Buildings.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.LoadAggregation.temporalSuperposition(6, {2.0, 1000000.0, 3.0, 1000000.0, 1000000.0}, {0.4, 0.0, 0.2, 1.0, 0.0}, 3) of type .Buildings.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.LoadAggregation.temporalSuperposition(Integer i, Real(quantity = "Power", unit = "W")[i] QAgg_flow, Real(quantity = "ThermalResistance", unit = "K/W")[i] kappa, Integer curCel) => Real(quantity = "ThermodynamicTemperature", unit = "K") in component candidates are .Buildings.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.LoadAggregation.temporalSuperposition(Integer i, Real(quantity = "Power", unit = "W")[i] QAgg_flow, Real(quantity = "ThermalResistance", unit = "K/W")[i] kappa, Integer curCel) => Real(quantity = "ThermodynamicTemperature", unit = "K") Error: Error occurred while flattening model Buildings.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.LoadAggregation.Validation.TemporalSuperposition