startTime=0 stopTime=86400 tolerance=1e-06 numberOfIntervals=2500 stepSize=34.56 Regular simulation: ./Buildings_8.0.0_Buildings.Obsolete.DistrictHeatingCooling.Validation.IdealSmallSystem -abortSlowSimulation -alarm=480 -lv LOG_STATS assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | hea1.pum.nominalValuesDefineDefaultPressureCurve assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | hea2.pum.nominalValuesDefineDefaultPressureCurve assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | coo1.pum.nominalValuesDefineDefaultPressureCurve assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | coo2.pum.nominalValuesDefineDefaultPressureCurve assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. stdout | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0858488s reading init.xml | | | | | | 0.0108365s reading info.xml | | | | | | 0.000193994s pre-initialization | | | | | | 0.000676979s [ 0.2%] initialization | | | | | | 3.7942e-05s [ 0.0%] steps | | | | | | 0s [ 0.0%] creating output-file | | | | | | 0.00128371s [ 0.4%] event-handling | | | | | | 0.0912231s [ 25.6%] overhead | | | | | | 0.26328s [ 73.8%] simulation | | | | | | 0.356696s [100.0%] total | | | | | events | | | | | | 4 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 698 steps taken | | | | | | 915 calls of functionODE | | | | | | 119 evaluations of jacobian | | | | | | 30 error test failures | | | | | | 0 convergence test failures | | | | | | 0.00999289s time of jacobian evaluation stdout | info | The simulation finished successfully.