Running: ./testmodel.py --libraries=/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_7.0.0_Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.OnlyExteriorWallWithWindowInteriorShade.conf.json Using package ModelicaServices with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 7.0.1 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/package.mo) Running command: translateModel(Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.OnlyExteriorWallWithWindowInteriorShade,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_7.0.0_Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.OnlyExteriorWallWithWindowInteriorShade") [:1:1-1:32:writable] Error: Class GC_set_max_heap_size not found in scope (looking for a function or record). Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/package.mo): time 2.015/2.015, allocations: 253.1 MB / 260.4 MB, free: 7.555 MB / 202.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001667/0.001667, allocations: 189.2 kB / 319.6 MB, free: 3.289 MB / 250.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 2.04/2.04, allocations: 205.4 MB / 0.5704 GB, free: 15.04 MB / 426.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.001318/0.001317, allocations: 98.36 kB / 0.6746 GB, free: 4.395 MB / 0.5105 GB Notification: Performance of FrontEnd - loaded program: time 1.238e-05/1.255e-05, allocations: 0 / 0.7843 GB, free: 102.5 MB / 0.5417 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.193/0.1931, allocations: 106.2 MB / 0.888 GB, free: 12.19 MB / 0.5573 GB Notification: Performance of FrontEnd - scodeFlatten: time 5.76/5.954, allocations: 2.333 GB / 3.221 GB, free: 40.41 MB / 0.8698 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0003495/5.954, allocations: 88.67 kB / 3.221 GB, free: 40.37 MB / 0.8698 GB [/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/HeatTransfer/Data/OpaqueConstructions.mo:9:4-11:111:writable] Error: Could not evaluate structural parameter (or constant): nLay which gives dimensions of array: material[nLay]. Array dimensions must be known at compile time. Error: Error occurred while flattening model Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.OnlyExteriorWallWithWindowInteriorShade