Running: ./testmodel.py --libraries=/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_7.0.0_Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.OnlyExteriorWallWithWindow.conf.json Using package ModelicaServices with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 7.0.1 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/package.mo) Running command: translateModel(Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.OnlyExteriorWallWithWindow,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_7.0.0_Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.OnlyExteriorWallWithWindow") [:1:1-1:32:writable] Error: Class GC_set_max_heap_size not found in scope (looking for a function or record). Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/package.mo): time 2.136/2.136, allocations: 253.1 MB / 260.4 MB, free: 7.641 MB / 202.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001644/0.001644, allocations: 193.2 kB / 319.6 MB, free: 3.32 MB / 250.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.89/1.89, allocations: 205.4 MB / 0.5704 GB, free: 14.96 MB / 426.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.001398/0.001398, allocations: 99.31 kB / 0.6746 GB, free: 4.32 MB / 0.5105 GB Notification: Performance of FrontEnd - loaded program: time 1.207e-05/1.222e-05, allocations: 4 kB / 0.7843 GB, free: 102.4 MB / 0.5417 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.2193/0.2194, allocations: 106.2 MB / 0.888 GB, free: 12.06 MB / 0.5573 GB Notification: Performance of FrontEnd - scodeFlatten: time 5.725/5.944, allocations: 2.333 GB / 3.221 GB, free: 40.43 MB / 0.8698 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.000362/5.945, allocations: 92.09 kB / 3.221 GB, free: 40.39 MB / 0.8698 GB [/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/HeatTransfer/Data/OpaqueConstructions.mo:9:4-11:111:writable] Error: Could not evaluate structural parameter (or constant): nLay which gives dimensions of array: material[nLay]. Array dimensions must be known at compile time. Error: Error occurred while flattening model Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.OnlyExteriorWallWithWindow