Running: ./testmodel.py --libraries=/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_7.0.0_Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases6xx.Case600FF.conf.json Using package ModelicaServices with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 7.0.1 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/package.mo) Running command: translateModel(Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases6xx.Case600FF,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_7.0.0_Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases6xx.Case600FF") [:1:1-1:32:writable] Error: Class GC_set_max_heap_size not found in scope (looking for a function or record). Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/package.mo): time 2.205/2.205, allocations: 253.1 MB / 260.4 MB, free: 7.516 MB / 202.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001634/0.001634, allocations: 185.2 kB / 319.6 MB, free: 3.293 MB / 250.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.842/1.842, allocations: 205.4 MB / 0.5704 GB, free: 15.03 MB / 426.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.001378/0.001378, allocations: 95.31 kB / 0.6746 GB, free: 4.395 MB / 0.5105 GB Notification: Performance of FrontEnd - loaded program: time 9.558e-06/9.798e-06, allocations: 0 / 0.7843 GB, free: 102.5 MB / 0.5417 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.2192/0.2193, allocations: 106.3 MB / 0.8881 GB, free: 12.16 MB / 0.5573 GB Notification: Performance of FrontEnd - scodeFlatten: time 5.866/6.085, allocations: 2.356 GB / 3.244 GB, free: 16.98 MB / 0.8698 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0004035/6.086, allocations: 106.1 kB / 3.244 GB, free: 16.93 MB / 0.8698 GB [/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/HeatTransfer/Data/GlazingSystems.mo:38:5-42:31:writable] Error: Dimensions must be parameter or constant expression (in size(glass, 1)). [/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/ThermalZones/Detailed/Validation/BESTEST/Cases6xx/Case600FF.mo:96:7-96:25:writable] Error: Component roo.datConExtWin[1].glaSys of variability PARAM has binding window600 of higher variability VAR. Error: Error occurred while flattening model Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases6xx.Case600FF