Running: ./testmodel.py --libraries=/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_7.0.0_Buildings.Fluid.HeatPumps.Validation.Carnot_TCon_etaPL.conf.json Using package ModelicaServices with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 7.0.1 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/package.mo) Running command: translateModel(Buildings.Fluid.HeatPumps.Validation.Carnot_TCon_etaPL,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_7.0.0_Buildings.Fluid.HeatPumps.Validation.Carnot_TCon_etaPL") [:1:1-1:32:writable] Error: Class GC_set_max_heap_size not found in scope (looking for a function or record). Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/package.mo): time 2.157/2.157, allocations: 253.1 MB / 260.4 MB, free: 7.5 MB / 202.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.002414/0.002414, allocations: 185.2 kB / 319.6 MB, free: 3.309 MB / 250.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.837/1.837, allocations: 205.4 MB / 0.5704 GB, free: 15.05 MB / 426.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.001356/0.001355, allocations: 91.38 kB / 0.6746 GB, free: 4.41 MB / 0.5105 GB Notification: Performance of FrontEnd - loaded program: time 1.333e-05/1.352e-05, allocations: 4 kB / 0.7843 GB, free: 102.6 MB / 0.5417 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.222/0.2221, allocations: 106.3 MB / 0.888 GB, free: 12.2 MB / 0.5573 GB Notification: Performance of FrontEnd - scodeFlatten: time 1.509/1.731, allocations: 415 MB / 1.293 GB, free: 260.5 MB / 0.8698 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0003129/1.731, allocations: 86.72 kB / 1.293 GB, free: 260.5 MB / 0.8698 GB [/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/Fluid/HeatPumps/Examples/Carnot_TCon.mo:17:3-31:71:writable] Error: Variable heaPum: Cyclically dependent constants or parameters found in scope Buildings.Fluid.HeatPumps.Carnot_TCon$heaPum: {COP_nominal,etaCarnot_nominal} (ignore with -d=ignoreCycles). Error: Error occurred while flattening model Buildings.Fluid.HeatPumps.Validation.Carnot_TCon_etaPL