Running: ./testmodel.py --libraries=/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_7.0.0_Buildings.Fluid.Chillers.Validation.Carnot_y_etaPL.conf.json Using package ModelicaServices with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 7.0.1 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/package.mo) Running command: translateModel(Buildings.Fluid.Chillers.Validation.Carnot_y_etaPL,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_7.0.0_Buildings.Fluid.Chillers.Validation.Carnot_y_etaPL") [:1:1-1:32:writable] Error: Class GC_set_max_heap_size not found in scope (looking for a function or record). Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/package.mo): time 2.318/2.318, allocations: 253.1 MB / 260.4 MB, free: 7.523 MB / 202.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.002426/0.002426, allocations: 177.3 kB / 319.6 MB, free: 3.316 MB / 250.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.883/1.883, allocations: 205.4 MB / 0.5704 GB, free: 14.97 MB / 426.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.001324/0.001324, allocations: 97.52 kB / 0.6746 GB, free: 4.328 MB / 0.5105 GB Notification: Performance of FrontEnd - loaded program: time 9.699e-06/9.858e-06, allocations: 0 / 0.7843 GB, free: 102.5 MB / 0.5417 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.2053/0.2054, allocations: 106.2 MB / 0.888 GB, free: 12.19 MB / 0.5573 GB Notification: Performance of FrontEnd - scodeFlatten: time 1.707/1.912, allocations: 404.9 MB / 1.283 GB, free: 260 MB / 0.8698 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0003991/1.913, allocations: 89 kB / 1.284 GB, free: 260 MB / 0.8698 GB [/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/Fluid/Chillers/Examples/Carnot_y.mo:22:3-36:67:writable] Error: Variable chi: Cyclically dependent constants or parameters found in scope Buildings.Fluid.Chillers.Carnot_y$chi: {COP_nominal,etaCarnot_nominal} (ignore with -d=ignoreCycles). Error: Error occurred while flattening model Buildings.Fluid.Chillers.Validation.Carnot_y_etaPL