Running: ./testmodel.py --libraries=/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_7.0.0_Buildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.IntegratedPrimarySecondary.conf.json Using package ModelicaServices with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 7.0.1 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/package.mo) Running command: translateModel(Buildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.IntegratedPrimarySecondary,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_7.0.0_Buildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.IntegratedPrimarySecondary") [:1:1-1:32:writable] Error: Class GC_set_max_heap_size not found in scope (looking for a function or record). Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/package.mo): time 2.08/2.08, allocations: 253.1 MB / 260.4 MB, free: 7.473 MB / 202.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001674/0.001674, allocations: 189.2 kB / 319.6 MB, free: 3.309 MB / 250.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.921/1.921, allocations: 205.4 MB / 0.5704 GB, free: 15.04 MB / 426.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.001469/0.001469, allocations: 102.4 kB / 0.6746 GB, free: 4.398 MB / 0.5105 GB Notification: Performance of FrontEnd - loaded program: time 1.659e-05/1.676e-05, allocations: 4 kB / 0.7843 GB, free: 102.5 MB / 0.5417 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.2535/0.2536, allocations: 106.2 MB / 0.888 GB, free: 12.19 MB / 0.5573 GB Notification: Performance of FrontEnd - scodeFlatten: time 1.797/2.051, allocations: 0.5014 GB / 1.389 GB, free: 202.2 MB / 0.8698 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0004243/2.051, allocations: 107.2 kB / 1.39 GB, free: 202.2 MB / 0.8698 GB [/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/Applications/DataCenters/ChillerCooled/Equipment/IntegratedPrimarySecondary.mo:121:11-121:21:writable] Error: Type mismatch in binding pressure = Buildings.Fluid.Movers.BaseClasses.Characteristics.flowParameters$intWSEPriSec1$perPum$pressure({0, 0}, {0, 0}), expected subtype of record Buildings.Fluid.Movers.BaseClasses.Characteristics.flowParameters Real(min = 0.0, quantity = "VolumeFlowRate", unit = "m3/s")[2] V_flow; Real(min = 0.0, displayUnit = "Pa", quantity = "Pressure", unit = "Pa")[2] dp; end Buildings.Fluid.Movers.BaseClasses.Characteristics.flowParameters;, got type record Buildings.Fluid.Movers.BaseClasses.Characteristics.flowParameters$intWSEPriSec1$perPum$pressure Integer[2] V_flow; Integer[2] dp; end Buildings.Fluid.Movers.BaseClasses.Characteristics.flowParameters$intWSEPriSec1$perPum$pressure;. Error: Error occurred while flattening model Buildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.IntegratedPrimarySecondary