Running: ./testmodel.py --libraries=/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_7.0.0_Buildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.IntegratedPrimaryLoadSide.conf.json Using package ModelicaServices with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 7.0.1 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/package.mo) Running command: translateModel(Buildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.IntegratedPrimaryLoadSide,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_7.0.0_Buildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.IntegratedPrimaryLoadSide") [:1:1-1:32:writable] Error: Class GC_set_max_heap_size not found in scope (looking for a function or record). Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/package.mo): time 2.075/2.075, allocations: 253.1 MB / 260.4 MB, free: 7.496 MB / 202.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.002344/0.002344, allocations: 177.3 kB / 319.6 MB, free: 3.324 MB / 250.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.984/1.984, allocations: 205.4 MB / 0.5704 GB, free: 15.12 MB / 426.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.001394/0.001394, allocations: 91.33 kB / 0.6746 GB, free: 4.48 MB / 0.5105 GB Notification: Performance of FrontEnd - loaded program: time 1.094e-05/1.119e-05, allocations: 0 / 0.7843 GB, free: 102.6 MB / 0.5417 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.216/0.216, allocations: 106.2 MB / 0.888 GB, free: 12.21 MB / 0.5573 GB Notification: Performance of FrontEnd - scodeFlatten: time 1.727/1.943, allocations: 0.5014 GB / 1.389 GB, free: 202.3 MB / 0.8698 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0003623/1.943, allocations: 107.5 kB / 1.39 GB, free: 202.3 MB / 0.8698 GB [/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/Applications/DataCenters/ChillerCooled/Equipment/Validation/IntegratedPrimaryLoadSide.mo:47:3-49:73:writable] Notification: From here: [/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/Applications/DataCenters/ChillerCooled/Equipment/Validation/BaseClasses/PartialPlant.mo:65:3-67:73:writable] Error: Duplicate elements (due to inherited elements) not identical: first element is: Modelica.Blocks.Sources.BooleanStep onChi(startTime(displayUnit = "h") = 7200) "On and off signal for the chiller" second element is: .Modelica.Blocks.Sources.BooleanStep onChi(startTime = 7200) "On and off signal for the chiller" Error: Error occurred while flattening model Buildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.IntegratedPrimaryLoadSide