Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_3.0.0_Buildings.Fluid.Interfaces.Examples.Humidifier_u.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 3.0.0/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.1+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.1+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.1+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica_StateGraph2 2.0.2/package.mo", uses=false) Using package Modelica_StateGraph2 with version 2.0.2 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica_StateGraph2 2.0.2/package.mo) Using package ModelicaServices with version 3.2.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.1+maint.om/package.mo) Using package Modelica with version 3.2.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.1+maint.om/package.mo) Using package Complex with version 3.2.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.1+maint.om/package.mo) Using package Buildings with version 3.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 3.0.0/package.mo) Running command: translateModel(Buildings.Fluid.Interfaces.Examples.Humidifier_u,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_3.0.0_Buildings.Fluid.Interfaces.Examples.Humidifier_u") translateModel(Buildings.Fluid.Interfaces.Examples.Humidifier_u,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_3.0.0_Buildings.Fluid.Interfaces.Examples.Humidifier_u") [:1:1-1:32:writable] Error: Class GC_set_max_heap_size not found in scope (looking for a function or record). Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 3.0.0/package.mo): time 0.7669/0.7669, allocations: 132.4 MB / 139.7 MB, free: 2.965 MB / 106.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.1+maint.om/package.mo): time 0.001303/0.001303, allocations: 175.5 kB / 171.6 MB, free: 5.039 MB / 138.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.1+maint.om/package.mo): time 1.339/1.339, allocations: 170.5 MB / 373.9 MB, free: 15.1 MB / 298.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.1+maint.om/package.mo): time 0.001936/0.001936, allocations: 100.1 kB / 444.4 MB, free: 14.07 MB / 314.7 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica_StateGraph2 2.0.2/package.mo:257:38-257:110:writable] Warning: The file was not encoded in UTF-8: "

An important practical aspect of state machines is the abilit...". Defaulting to 7-bit ASCII with unknown characters replaced by '?'. To change encoding when loading a file: loadFile(encoding="ISO-XXXX-YY"). To change it in a package: add a file package.encoding at the top-level. Note: The Modelica Language Specification only allows files encoded in UTF-8. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica_StateGraph2 2.0.2/package.mo:761:36-761:108:writable] Warning: The file was not encoded in UTF-8: "

The Modelica_StateGraph2 library is described in detail in (O...". Defaulting to 7-bit ASCII with unknown characters replaced by '?'. To change encoding when loading a file: loadFile(encoding="ISO-XXXX-YY"). To change it in a package: add a file package.encoding at the top-level. Note: The Modelica Language Specification only allows files encoded in UTF-8. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica_StateGraph2 2.0.2/package.mo:1435:36-1435:108:writable] Warning: The file was not encoded in UTF-8: "

Main Authors:
SCode: time 0.1565/0.1565, allocations: 73.39 MB / 0.666 GB, free: 15.95 MB / 410.7 MB Notification: Performance of FrontEnd - scodeFlatten: time 5.47/5.627, allocations: 2.216 GB / 2.882 GB, free: 125.6 MB / 0.6042 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002354/5.627, allocations: 87.95 kB / 2.882 GB, free: 125.6 MB / 0.6042 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 3.0.0/Fluid/Interfaces/LumpedVolumeDeclarations.mo:3:15-5:45:writable] Notification: From here: [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 3.0.0/Fluid/Interfaces/Examples/Humidifier_u.mo:8:3-17:54:writable] Error: component hea1 contains the definition of a partial class Medium. Please redeclare it to any package compatible with Modelica.Media.Interfaces.PartialMedium. Error: Error occurred while flattening model Buildings.Fluid.Interfaces.Examples.Humidifier_u