startTime=0 stopTime=20000 tolerance=1e-06 numberOfIntervals=2500 stepSize=8 Regular simulation: ./BuildingSystems_BuildingSystems.Technologies.Cogeneration.Examples.CogenerationUnitWithStorage -abortSlowSimulation -alarm=480 -lv LOG_STATS assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | pump.nominalValuesDefineDefaultPressureCurve assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. stdout | info | The initialization finished successfully without homotopy method. assert | debug | division leads to inf or nan at time 17194.4, (a=0) / (b=0), where divisor b is: CHP.etaEl.y[1]