Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr BuildingSystems_BuildingSystems.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.Validation.Analytic_20Years.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/NcDataReader2 2.5.1-master/package.mo", uses=false) Using package NcDataReader2 with version 2.5.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/NcDataReader2 2.5.1-master/package.mo) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Using package Modelica with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package BuildingSystems with version 2.0.0-beta (/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/package.mo) Running command: translateModel(BuildingSystems.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.Validation.Analytic_20Years,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="BuildingSystems_BuildingSystems.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.Validation.Analytic_20Years") translateModel(BuildingSystems.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.Validation.Analytic_20Years,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="BuildingSystems_BuildingSystems.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.Validation.Analytic_20Years") [:1:1-1:32:writable] Error: Class GC_set_max_heap_size not found in scope (looking for a function or record). Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/package.mo): time 0.7441/0.7441, allocations: 141.8 MB / 149.1 MB, free: 13.02 MB / 138.9 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.001166/0.001166, allocations: 176 kB / 181.9 MB, free: 9.73 MB / 154.9 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo): time 1.418/1.418, allocations: 221.3 MB / 436 MB, free: 2.211 MB / 330.9 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.001019/0.001019, allocations: 95.52 kB / 0.507 GB, free: 17.73 MB / 378.9 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/NcDataReader2 2.5.1-master/package.mo): time 0.001826/0.001826, allocations: 280.2 kB / 0.5884 GB, free: 3.711 MB / 442.9 MB Notification: Performance of FrontEnd - loaded program: time 9.558e-06/9.588e-06, allocations: 1.344 kB / 0.6759 GB, free: 136.5 MB / 0.5107 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.1859/0.1859, allocations: 82.78 MB / 0.7568 GB, free: 83 MB / 0.5107 GB Notification: Performance of FrontEnd - scodeFlatten: time 0.4938/0.6797, allocations: 139.2 MB / 0.8927 GB, free: 89.35 MB / 0.5575 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0003401/0.6801, allocations: 108.8 kB / 0.8928 GB, free: 89.35 MB / 0.5575 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/Geothermal/Borefields/BaseClasses/HeatTransfer/GroundTemperatureResponse.mo:8:3-10:87:writable] Error: Array equation has unknown size in groTemRes.borFieDat.conDat.cooBor=borFieDat.conDat.cooBor. Error: Internal error - InstUtil.moveBindings: Mismatched number of equations and variables. Error: Error occurred while flattening model BuildingSystems.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.Validation.Analytic_20Years