Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr BuildingSystems_BuildingSystems.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.LoadAggregation.Validation.TemporalSuperposition.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/NcDataReader2 2.5.1-master/package.mo", uses=false) Using package NcDataReader2 with version 2.5.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/NcDataReader2 2.5.1-master/package.mo) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Using package Modelica with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package BuildingSystems with version 2.0.0-beta (/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/package.mo) Running command: translateModel(BuildingSystems.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.LoadAggregation.Validation.TemporalSuperposition,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="BuildingSystems_BuildingSystems.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.LoadAggregation.Validation.TemporalSuperposition") translateModel(BuildingSystems.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.LoadAggregation.Validation.TemporalSuperposition,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="BuildingSystems_BuildingSystems.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.LoadAggregation.Validation.TemporalSuperposition") [:1:1-1:32:writable] Error: Class GC_set_max_heap_size not found in scope (looking for a function or record). Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/package.mo): time 0.751/0.751, allocations: 141.8 MB / 149.1 MB, free: 4.492 MB / 122.9 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.001121/0.001121, allocations: 183.5 kB / 181.9 MB, free: 184 kB / 138.9 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo): time 1.341/1.341, allocations: 221.4 MB / 436 MB, free: 9.285 MB / 330.9 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.001084/0.001084, allocations: 99.41 kB / 0.507 GB, free: 24.17 MB / 394.9 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/NcDataReader2 2.5.1-master/package.mo): time 0.001797/0.001797, allocations: 273.9 kB / 0.5884 GB, free: 12.34 MB / 442.9 MB Notification: Performance of FrontEnd - loaded program: time 9.087e-06/9.257e-06, allocations: 0 / 0.6759 GB, free: 2.664 MB / 0.5107 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.4584/0.4584, allocations: 82.76 MB / 0.7568 GB, free: 113 MB / 0.5263 GB Notification: Performance of FrontEnd - scodeFlatten: time 0.1098/0.5682, allocations: 108 MB / 0.8623 GB, free: 4.793 MB / 0.5263 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002126/0.5685, allocations: 104.4 kB / 0.8624 GB, free: 4.695 MB / 0.5263 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/Geothermal/Borefields/BaseClasses/HeatTransfer/LoadAggregation/Validation/TemporalSuperposition.mo:5:3-10:41:writable] Error: No matching function found for BuildingSystems.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.LoadAggregation.temporalSuperposition(6, {2.0, 1000000.0, 3.0, 1000000.0, 1000000.0}, {0.4, 0.0, 0.2, 1.0, 0.0}, 3) of type .BuildingSystems.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.LoadAggregation.temporalSuperposition(Integer i, Real(quantity = "Power", unit = "W")[i] QAgg_flow, Real(quantity = "ThermalResistance", unit = "K/W")[i] kappa, Integer curCel) => Real(quantity = "ThermodynamicTemperature", unit = "K") in component candidates are .BuildingSystems.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.LoadAggregation.temporalSuperposition(Integer i, Real(quantity = "Power", unit = "W")[i] QAgg_flow, Real(quantity = "ThermalResistance", unit = "K/W")[i] kappa, Integer curCel) => Real(quantity = "ThermodynamicTemperature", unit = "K") Error: Error occurred while flattening model BuildingSystems.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.LoadAggregation.Validation.TemporalSuperposition