Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Annex60_1.0.0_Annex60.Fluid.HeatPumps.Validation.Carnot_TCon_etaPL.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Annex60 1.0.0/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.2+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.2+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.2+maint.om/package.mo", uses=false) Using package ModelicaServices with version 3.2.2 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.2+maint.om/package.mo) Using package Modelica with version 3.2.2 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.2+maint.om/package.mo) Using package Complex with version 3.2.2 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.2+maint.om/package.mo) Using package Annex60 with version 1.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Annex60 1.0.0/package.mo) Running command: translateModel(Annex60.Fluid.HeatPumps.Validation.Carnot_TCon_etaPL,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Annex60_1.0.0_Annex60.Fluid.HeatPumps.Validation.Carnot_TCon_etaPL") translateModel(Annex60.Fluid.HeatPumps.Validation.Carnot_TCon_etaPL,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Annex60_1.0.0_Annex60.Fluid.HeatPumps.Validation.Carnot_TCon_etaPL") [:1:1-1:32:writable] Error: Class GC_set_max_heap_size not found in scope (looking for a function or record). Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Annex60 1.0.0/package.mo): time 0.3021/0.3021, allocations: 54.39 MB / 61.68 MB, free: 15.14 MB / 62.07 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.2+maint.om/package.mo): time 0.001163/0.001163, allocations: 188.4 kB / 75.39 MB, free: 1.406 MB / 62.07 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.2+maint.om/package.mo): time 1.65/1.65, allocations: 194.2 MB / 283.2 MB, free: 7.625 MB / 222.1 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.2+maint.om/package.mo): time 0.001698/0.001698, allocations: 109.3 kB / 341.3 MB, free: 13.47 MB / 286.1 MB Notification: Performance of FrontEnd - loaded program: time 6.823e-06/6.853e-06, allocations: 0 / 404.9 MB, free: 31.61 MB / 286.1 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.1417/0.1417, allocations: 57.64 MB / 462.6 MB, free: 5.879 MB / 318.1 MB Notification: Performance of FrontEnd - scodeFlatten: time 0.9068/1.049, allocations: 360.3 MB / 0.8036 GB, free: 39.83 MB / 494.1 MB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002823/1.049, allocations: 86.2 kB / 0.8037 GB, free: 39.79 MB / 494.1 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Annex60 1.0.0/Fluid/HeatPumps/Examples/Carnot_TCon.mo:17:3-31:71:writable] Error: Variable heaPum: Cyclically dependent constants or parameters found in scope Annex60.Fluid.HeatPumps.Carnot_TCon$heaPum: {COP_nominal,etaCarnot_nominal} (ignore with -d=ignoreCycles). Error: Error occurred while flattening model Annex60.Fluid.HeatPumps.Validation.Carnot_TCon_etaPL