Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Annex60_1.0.0_Annex60.Fluid.Chillers.Validation.Carnot_TEva_etaPL.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Annex60 1.0.0/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.2+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.2+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.2+maint.om/package.mo", uses=false) Using package ModelicaServices with version 3.2.2 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.2+maint.om/package.mo) Using package Modelica with version 3.2.2 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.2+maint.om/package.mo) Using package Complex with version 3.2.2 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.2+maint.om/package.mo) Using package Annex60 with version 1.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Annex60 1.0.0/package.mo) Running command: translateModel(Annex60.Fluid.Chillers.Validation.Carnot_TEva_etaPL,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Annex60_1.0.0_Annex60.Fluid.Chillers.Validation.Carnot_TEva_etaPL") translateModel(Annex60.Fluid.Chillers.Validation.Carnot_TEva_etaPL,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Annex60_1.0.0_Annex60.Fluid.Chillers.Validation.Carnot_TEva_etaPL") [:1:1-1:32:writable] Error: Class GC_set_max_heap_size not found in scope (looking for a function or record). Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Annex60 1.0.0/package.mo): time 0.2781/0.2781, allocations: 54.4 MB / 61.68 MB, free: 1.84 MB / 50.85 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.2+maint.om/package.mo): time 0.001289/0.001289, allocations: 185.2 kB / 75.38 MB, free: 10.62 MB / 66.85 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.2+maint.om/package.mo): time 1.541/1.541, allocations: 194.2 MB / 283.2 MB, free: 9.836 MB / 226.8 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.2+maint.om/package.mo): time 0.001711/0.00171, allocations: 102.9 kB / 341.2 MB, free: 2.352 MB / 258.8 MB Notification: Performance of FrontEnd - loaded program: time 8.526e-06/8.556e-06, allocations: 0 / 404.9 MB, free: 2.613 MB / 322.8 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.1513/0.1513, allocations: 57.64 MB / 462.6 MB, free: 8.891 MB / 386.8 MB Notification: Performance of FrontEnd - scodeFlatten: time 0.8412/0.9926, allocations: 360.2 MB / 0.8035 GB, free: 7.922 MB / 482.8 MB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002587/0.9929, allocations: 96.56 kB / 0.8036 GB, free: 7.871 MB / 482.8 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Annex60 1.0.0/Fluid/Chillers/Examples/Carnot_TEva.mo:19:3-33:70:writable] Error: Variable chi: Cyclically dependent constants or parameters found in scope Annex60.Fluid.Chillers.Carnot_TEva$chi: {COP_nominal,etaCarnot_nominal} (ignore with -d=ignoreCycles). Error: Error occurred while flattening model Annex60.Fluid.Chillers.Validation.Carnot_TEva_etaPL