Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Annex60_1.0.0_Annex60.Fluid.Chillers.Validation.Carnot_TEva_HighTemperature.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Annex60 1.0.0/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.2+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.2+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.2+maint.om/package.mo", uses=false) Using package ModelicaServices with version 3.2.2 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.2+maint.om/package.mo) Using package Modelica with version 3.2.2 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.2+maint.om/package.mo) Using package Complex with version 3.2.2 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.2+maint.om/package.mo) Using package Annex60 with version 1.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Annex60 1.0.0/package.mo) Running command: translateModel(Annex60.Fluid.Chillers.Validation.Carnot_TEva_HighTemperature,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Annex60_1.0.0_Annex60.Fluid.Chillers.Validation.Carnot_TEva_HighTemperature") translateModel(Annex60.Fluid.Chillers.Validation.Carnot_TEva_HighTemperature,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Annex60_1.0.0_Annex60.Fluid.Chillers.Validation.Carnot_TEva_HighTemperature") [:1:1-1:32:writable] Error: Class GC_set_max_heap_size not found in scope (looking for a function or record). Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Annex60 1.0.0/package.mo): time 0.2829/0.2829, allocations: 54.4 MB / 61.68 MB, free: 11.15 MB / 58.72 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.2+maint.om/package.mo): time 0.001572/0.001572, allocations: 187.1 kB / 75.37 MB, free: 1.523 MB / 58.72 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.2+maint.om/package.mo): time 1.498/1.498, allocations: 194.2 MB / 283.2 MB, free: 3.492 MB / 218.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.2+maint.om/package.mo): time 0.001818/0.001818, allocations: 117.2 kB / 341.3 MB, free: 9.375 MB / 282.7 MB Notification: Performance of FrontEnd - loaded program: time 1.092e-05/1.095e-05, allocations: 0 / 404.9 MB, free: 27.69 MB / 282.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.1547/0.1547, allocations: 57.65 MB / 462.6 MB, free: 1.969 MB / 314.7 MB Notification: Performance of FrontEnd - scodeFlatten: time 0.927/1.082, allocations: 360.2 MB / 0.8035 GB, free: 32.43 MB / 490.7 MB Notification: Performance of FrontEnd - mkProgramGraph: time 0.000236/1.082, allocations: 89.27 kB / 0.8036 GB, free: 32.39 MB / 490.7 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Annex60 1.0.0/Fluid/Chillers/Examples/Carnot_TEva.mo:19:3-33:70:writable] Error: Variable chi: Cyclically dependent constants or parameters found in scope Annex60.Fluid.Chillers.Carnot_TEva$chi: {COP_nominal,etaCarnot_nominal} (ignore with -d=ignoreCycles). Error: Error occurred while flattening model Annex60.Fluid.Chillers.Validation.Carnot_TEva_HighTemperature