Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr ThermoSysPro_ThermoSysPro.Fluid.Examples.SimpleExamples.TestDiffusion_DynamicPlateHeatExchanger.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/package.mo", uses=false) Using package ThermoSysPro with version 4.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/package.mo) Running command: "" <> buildModelFMU(ThermoSysPro.Fluid.Examples.SimpleExamples.TestDiffusion_DynamicPlateHeatExchanger,fileNamePrefix="ThermoSysPro_ThermoSysPro_Fluid_Examples_SimpleExamples_TestDiffusion_DynamicPlateHeatExchanger",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(ThermoSysPro.Fluid.Examples.SimpleExamples.TestDiffusion_DynamicPlateHeatExchanger,fileNamePrefix="ThermoSysPro_ThermoSysPro_Fluid_Examples_SimpleExamples_TestDiffusion_DynamicPlateHeatExchanger",fmuType="me",version="2.0",platforms={"static"}) [:1:1-1:32:writable] Error: Class GC_set_max_heap_size not found in scope (looking for a function or record). Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/package.mo): time 0.638/0.638, allocations: 149.6 MB / 156.9 MB, free: 0.7266 MB / 130.8 MB Notification: Performance of FrontEnd - loaded program: time 0.09328/0.7313, allocations: 35.93 MB / 192.9 MB, free: 8.316 MB / 162.8 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.04947/0.7808, allocations: 31.98 MB / 224.8 MB, free: 8.352 MB / 194.8 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Units.mo:6:5-6:35:writable] Error: Base class Modelica.Icons.Package not found in scope ThermoSysPro.Units.SI. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Units.mo:2:1-1196:10:writable] Error: Class SI.ThermalConductivity not found in scope ThermoSysPro.Units. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicPlateHeatExchanger.mo:7:3-8:33:writable] Error: Class Units.SI.ThermalConductivity not found in scope ThermoSysPro.Fluid.HeatExchangers.DynamicPlateHeatExchanger. Error: Error occurred while flattening model ThermoSysPro.Fluid.Examples.SimpleExamples.TestDiffusion_DynamicPlateHeatExchanger Error: Internal error SimCode: The model ThermoSysPro.Fluid.Examples.SimpleExamples.TestDiffusion_DynamicPlateHeatExchanger could not be translated to FMU