Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr PowerSystems_latest_PowerSystems.Examples.AC3ph.Generation.TieLine.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerSystems 1.0.1-master/package.mo", uses=false) Using package PowerSystems with version 1.0.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerSystems 1.0.1-master/package.mo) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Running command: "" <> buildModelFMU(PowerSystems.Examples.AC3ph.Generation.TieLine,fileNamePrefix="PowerSystems_latest_PowerSystems_Examples_AC3ph_Generation_TieLine",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(PowerSystems.Examples.AC3ph.Generation.TieLine,fileNamePrefix="PowerSystems_latest_PowerSystems_Examples_AC3ph_Generation_TieLine",fmuType="me",version="2.0",platforms={"static"}) [:1:1-1:32:writable] Error: Class GC_set_max_heap_size not found in scope (looking for a function or record). Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001562/0.001562, allocations: 187.4 kB / 8.133 MB, free: 2.203 MB / 5.871 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.136/1.136, allocations: 205.2 MB / 213.7 MB, free: 13.92 MB / 186.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.0008516/0.0008517, allocations: 101.6 kB / 261.8 MB, free: 13.54 MB / 218.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerSystems 1.0.1-master/package.mo): time 0.1592/0.1592, allocations: 37.97 MB / 347.7 MB, free: 7.477 MB / 298.7 MB Notification: Performance of FrontEnd - loaded program: time 0.1635/0.3227, allocations: 62.44 MB / 410.1 MB, free: 46.76 MB / 298.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.08282/0.4056, allocations: 56.31 MB / 466.4 MB, free: 6.371 MB / 314.7 MB Notification: Performance of FrontEnd - scodeFlatten: time 0.2978/0.7034, allocations: 143.9 MB / 0.596 GB, free: 14.52 MB / 442.7 MB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002682/0.7038, allocations: 91.95 kB / 0.5961 GB, free: 14.43 MB / 442.7 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerSystems 1.0.1-master/AC3ph/Machines.mo:2240:3-2240:48:writable] Error: Could not evaluate structural parameter (or constant): n_d which gives dimensions of array: L_rd[n_d]. Array dimensions must be known at compile time. Error: Error occurred while flattening model PowerSystems.Examples.AC3ph.Generation.TieLine Error: Internal error SimCode: The model PowerSystems.Examples.AC3ph.Generation.TieLine could not be translated to FMU