Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr PowerGrids_PowerGrids.Electrical.Test.TwoBusesPowerTransferTransmissionLine.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 1.0.2-master/package.mo", uses=false) Using package PowerGrids with version 1.0.2 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 1.0.2-master/package.mo) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Running command: "" <> buildModelFMU(PowerGrids.Electrical.Test.TwoBusesPowerTransferTransmissionLine,fileNamePrefix="PowerGrids_PowerGrids_Electrical_Test_TwoBusesPowerTransferTransmissionLine",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(PowerGrids.Electrical.Test.TwoBusesPowerTransferTransmissionLine,fileNamePrefix="PowerGrids_PowerGrids_Electrical_Test_TwoBusesPowerTransferTransmissionLine",fmuType="me",version="2.0",platforms={"static"}) [:1:1-1:32:writable] Error: Class GC_set_max_heap_size not found in scope (looking for a function or record). Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.003549/0.003549, allocations: 179.7 kB / 7.455 MB, free: 2.512 MB / 5.871 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.7/1.7, allocations: 205.2 MB / 213.1 MB, free: 13.85 MB / 186.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.00102/0.00102, allocations: 91.56 kB / 261.1 MB, free: 13.54 MB / 218.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 1.0.2-master/package.mo): time 0.05769/0.05769, allocations: 14.03 MB / 323 MB, free: 15.45 MB / 282.7 MB Notification: Performance of FrontEnd - loaded program: time 0.2632/0.321, allocations: 57.23 MB / 380.3 MB, free: 74.16 MB / 298.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.1261/0.4471, allocations: 51.1 MB / 431.4 MB, free: 23.07 MB / 298.7 MB Notification: Performance of FrontEnd - scodeFlatten: time 0.4956/0.9428, allocations: 83.64 MB / 0.5029 GB, free: 10.91 MB / 330.7 MB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002919/0.9432, allocations: 71.59 kB / 0.503 GB, free: 10.91 MB / 330.7 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 1.0.2-master/Electrical/BaseClasses/PortAC.mo:49:3-50:32:writable] Error: Variable S.re not found in scope PowerGrids.Electrical.BaseClasses.PortAC$infiniteBusA$port. Error: Error occurred while flattening model PowerGrids.Electrical.Test.TwoBusesPowerTransferTransmissionLine Error: Internal error SimCode: The model PowerGrids.Electrical.Test.TwoBusesPowerTransferTransmissionLine could not be translated to FMU