Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr PowerGrids_PowerGrids.Electrical.Test.TwoBusesInductiveTransmissionLine.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 1.0.2-master/package.mo", uses=false) Using package PowerGrids with version 1.0.2 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 1.0.2-master/package.mo) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Running command: "" <> buildModelFMU(PowerGrids.Electrical.Test.TwoBusesInductiveTransmissionLine,fileNamePrefix="PowerGrids_PowerGrids_Electrical_Test_TwoBusesInductiveTransmissionLine",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(PowerGrids.Electrical.Test.TwoBusesInductiveTransmissionLine,fileNamePrefix="PowerGrids_PowerGrids_Electrical_Test_TwoBusesInductiveTransmissionLine",fmuType="me",version="2.0",platforms={"static"}) [:1:1-1:32:writable] Error: Class GC_set_max_heap_size not found in scope (looking for a function or record). Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.005284/0.005284, allocations: 179.5 kB / 7.455 MB, free: 2.242 MB / 5.871 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.651/1.651, allocations: 205.2 MB / 213.1 MB, free: 13.85 MB / 186.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.001004/0.001003, allocations: 96.77 kB / 261.1 MB, free: 13.6 MB / 218.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 1.0.2-master/package.mo): time 0.05925/0.05925, allocations: 14.03 MB / 323 MB, free: 15.5 MB / 282.7 MB Notification: Performance of FrontEnd - loaded program: time 0.2597/0.319, allocations: 57.23 MB / 380.3 MB, free: 74.17 MB / 298.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.1334/0.4524, allocations: 51.1 MB / 431.4 MB, free: 23.08 MB / 298.7 MB Notification: Performance of FrontEnd - scodeFlatten: time 0.4618/0.9143, allocations: 83.63 MB / 0.5029 GB, free: 10.98 MB / 330.7 MB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002241/0.9146, allocations: 72.56 kB / 0.503 GB, free: 10.98 MB / 330.7 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 1.0.2-master/Electrical/BaseClasses/PortAC.mo:49:3-50:32:writable] Error: Variable S.re not found in scope PowerGrids.Electrical.BaseClasses.PortAC$infiniteBusA$port. Error: Error occurred while flattening model PowerGrids.Electrical.Test.TwoBusesInductiveTransmissionLine Error: Internal error SimCode: The model PowerGrids.Electrical.Test.TwoBusesInductiveTransmissionLine could not be translated to FMU